8 0027364-00_BEDBWRTAQP 12/2021 •
repa
BAD GmbH • We reserve the right to make technical changes. All dimensions in cm.
- Remove the drain cover (4) together with the drain plug (5)
by lifting it upwards
Attention:
The plug is only loosely fitted, it can
fall out and damage the bath
- Clean the filter (6)
- You can adjust the drain plug using the adjustment screw (7)
4
5
7
6
Connection
Via separately connected electricity supply
Separate 2-pin residual current
circuit breaker mandatory:
RCD with I
Δ
N ≤ 30 mA (overvoltage category III)
Supply voltage
230 V AC, 50 Hz
Fuse without
16 A-B for 3 x 1.5 mm² supply line
supplementary heating
Connected load
0.7 kW (back therapy)
0.8 kW (Aquapuncture)
12 TECHNICAL DATA
11 TROUBLESHOOTING TECHNICAL PROBLEMS
Servicing / technical data
10
CLEANING THE DRAIN FILTER,
ADJUSTING THE DRAIN PLUG
PROBLEM
1. No display on control panel
2. Key flashes when
pressed
3. Pump switches off
automatically.
4. Irregular water pump
suction. Fluctuating
water nozzle output
SOLUTION
- Check the electricity supply
- Not enough water in the bath
- Fill up the bath to approx. 5-8 cm above the top nozzles
- The system switches off automatically after around
20 min. via a timer. You can then reactivate it
immediately.
- Not enough water/water loss (see 2.)
- Drain outlet is blocked/drain plug is incorrectly positioned.
Tighten the adjustment screws by approx. 2-3 mm.
- Adjust at the plug (see section 10)