Amplitude (feed rate)
0... 100 %
A.
0 %
000, 008
Maximum output voltage
5...100 %
P
90 %.
096, 008
Vibrating frequency
5...300 Hz
F.
100 Hz
096, 008
Soft start ramp up
0... 60 sec.
/.
0.1 sec.
096
Soft stop ramp down
0... 60 sec.
\.
0.1 sec.
096
External setpoint
0 / I
E.S.P.
0
003
Potentiometer setpoint
0 / I
POT.
0
003
Setpoint 0(4)... 20 mA
0 / I
4.20
0
003
Coarse / Fine control
0 / I
2.SP.
0
003
Invert enable
0 / I
-En.
0
003
Switch on time delay
0... 60 sec.
I.
1.0 sec.
007, 167
Switch off time delay
0... 60 sec.
0.
1.0 sec.
007, 167
Invert sensor
PNP/PNP invers -SE.
PNP
007, 167
Activate sensor timeout
0 / I
E.En.
0
015
Sensor timeout delay
1... 240 sec.
E.
180 sec.
015
Switch off time air valve
0...60 sec.
Ai.
4 sec.
015
Activate control mode
0 / I
ACC.
0
008
P characteristic
0...100
P.A.
40
008
I characteristic
0...100
I.A.
100
008
Automatic frequency control ON
0 / I
A.F.C.
0
008
Automatic frequency search ON
A.F.S. 008
Display output current
i. 040
Display output frequency
F. 040
Pulse feed
0 / I
HOP.
0
064
On time delay (only if HOP = I)
0..60 sec.
H.
1.0 sec.
064
Off time delay (only if HOP = I)
0..60 sec.
h.
1.0 sec.
064
Invert Hopper sensor (not active)
0 / I
-Ho.
0
064
Save user settings
0...3 PUSH. 0
143
Restore factory settings
FAC.
210
Restore user settings
0...3
US.PA. 0
210
Hide programming menus
0 / I
Hd.C.
0
117
Hide setpoint adjustment
0 / I di.S. 0 137
Display software version
001
Settings
Range
Code
Factory
Menu
settings
code
Input voltage too high
Error messages must be cleared in Menu no. C 009 by means of 'Cl.err.'
Possible cause: Incorrect wiring, possibly a defective coil.
Cause: Mains voltage too high or induced voltage from coil
Overload (output curr
ent too high).
Possible cause: Feeder too large, freq
uency too low for
installed coils, air gap too large.
Short-circuited output
Error messages
Timeout can be cleared with the 'I' key or by means of enable
Code 000 Feed rate set point
Feed rate 0...100 %
Operating mode
A
m
p
lit
u
d
e
Feed rate
Setpoint
No code number is required to change the feed rate: pressing the P key twice will call the setpoint display.
Feed rate setting
Sensor timeout has elasped (material sensor)
Sensor fault (only in regulation mode)
Accelerometer missing or faulty
Current spike limit
Frequency set too low for installed coil or frequency
altered too rapidly during setting up
Frequently appearing Errors, which are not described in this chapter,
should be reported to the manufacturer.