REO REOVIB 514 Скачать руководство пользователя страница 1

Operating Instructions

 

 

REOVIB 514

 

ID No. 51401

 

 

 

 

REO ELEKTRONIK AG 

                                           

                   5140110_EN_09-12.DOC

 

 

 

                

27.02.2012 

 

 

 

Thyristor control units for use with vibratory feeder units 

 
The REOVIB 514 range of control units are suitable for powering vibratory feeders which have a mechanical vibrating frequency 
which  the  same  as, or double that of mains frequency. The adjustment of feeder throughput is achieved by using a triac with 
phase angle control. The set point for the feeder throughput can be derived from a potentiometer, a signal voltage 0…10 V or a 
signal  current  0/4…20  mA.  The  set  point  input  is  isolated  from  live  mains.  The  set  point  range  can  be  adjusted  to  suit  the 
feeder unit by using trimmers “Umin “ / “Umax”  (see “effects of trimmers Umin / Umax”). 
The units can operate with feeders which have a mechanical vibrating frequency of 50 Hz or 100 Hz, ie 3000/6000 vibs/min (for 
60Hz mains supply this would be 60 Hz or 100 Hz, ie 3600/7200 vibs/min). The mechanical frequency is determined, externally, 
by the use of a link between terminals 19 and 20; without link = 50 Hz or 3000 vibs/min and with link = 100 Hz or 6000 vibs/min. 
An enable input is provided on terminals 8, 9 and 10 for power free switching of the output (eg from a PLC). This input can be 
operated from external contacts or with a signal voltage 12...24 V. The unit is enabled when the contacts are closed or when a 
signal voltage is applied. The enable input is isolated from the mains. An additional control input is provided on terminals 1 and 
2 for use with other control units, such as a track controller. When these inputs are not used, then each pair of terminals 1and 
2, as well as 8 and 9 must be linked.  
The unit is supplied in a simple to install modular housing which is suitable for both DIN rail mounting (EN 50022-35) and back 
panel mounting. The terminals have safety covers, according to VBG 4 standards. 
 
Technical data 
  

Type REOVIB  514 

51401 

Supply voltage 

230 V, + 6 % / - 10 %, 50/60 Hz 

Output voltage 

0…210 V 

Output current 

0.5…6 A 

Set point source 

Potentiometer 10 k

 

0…10 V, DC      Ri 20 k

 

0…20 mA          Ri 500 

 

Enable input 

Contact / 12…24 V, DC signal voltage Ri 10 k

 

Ambient operating temperature 

0…45 

O

Dimensions (h x w x d) 

74 x 100 x 125,5 mm 

Enclosure standard 

VBG 4 

Other standards 

EN 61000-6-2, EN 61000-6-4, VDE 0160 

Fuse 

FF 10 A (5 x 20 mm) 

 

 
 
 

 
 
 
Ordering Code:  

REOVIB 51401 

ID No.: 51401.10 

 
 
 
 

 

100

7

4

C   125,5

C1      106,5

U
E
E

1

2

Umax

Umin

REOVIB 514