Operating Instructions  

REOVIB 506 

ID Nr. 50606

 

REO-USA, Inc.

 

 

 

Technical Safety Information for the User 

 

This des cription contains the necessary information for the correct application of the product described below. It is intended for use 
by technically qualified personal. 

 

Safety Instructions 

The following instructions are provided for the personal safety of operators and also for the protection of the described product and 
connected equipment. 

 

Warning!

 

Hazardous Voltage. 
Failure to observe can kill, cause serious injury or damage.  

 

• 

Isolate from mains before installation or dismantling work, as well as for fuse changes or post installation modifications.  

• 

Observe the prescribed accident prevention and safety rules for the specific application. 

• 

Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage. 

• 

Emergency stop devices must be provided for all applications. Opearation of the emergency stop must inhibit any further 
uncontrolled operation. 

• 

The electric connections must be covered!

 

• 

Earth connection must be checked for safe function after assembly!

 

 

Connection draw ing and Settings 

 

The switch-over of the mechanical vibrating frequency and the effect of the control input inhibit/enable are realised with the jumpers 
S1 and S2. To do this, it is necessary to remove the left side cheek of the enclosure. 

 

Attention! 

This input is at mains potential! 

 
 

 
 
 
 
 

Adjustment: 
 

• 

Connect controller according to diagram. 

• 

Adjust setpoint to minimum and inhibit unit. 

• 

Switch on mains supply and enable unit. 

• 

Slowly increase the setpoint to maximum and monitor  
the load condition (if possible measure the voltage and current). 

• 

On reaching maximum, limit the output with trimmer 
U

max

 and then set the minimum set point value with 

trimmer U

min

!

 

!

 

Change-over vibrating frequency

Change-over Inhibit/Enable

3000 / min (50Hz)

6000 / min (100Hz)

Enable

Inhibit

Power ON

Power OFF

1

S1

S2

1 2

1 2

24V /

24V /

Power ON

Power OFF

-

+

Inhibit

24V

Setpoint

10K Ohm

A

S

E

1

Umax

Umin

REOVIB 506

2

3

4

5

8

9

10

230V, 50/60Hz

L

N

PE

Load

0

10 20 30 40 50 60 70 80 90 100 [%]

10

20

30

40

50

60

70

80

90

100

[%]

Output voltage

Set point

Umin

Umax

Adjustment range

Effects of the min. and max. trimmer

Only use Type FF 5A semiconductor
 fuses as replacement!

1

Umax

Umin

2

3

4

5

A

S

E

10K Ohm

Control cables should be laid separate
from other cables or should be screened.

Inhibit/Enable using signal
voltage 12...24 V, DC

Inhibit/Enable using 
contact

ELEKTRONIK