Operating Instructions
REOVIB 506
ID Nr. 50606
REO-USA, Inc.
Technical Safety Information for the User
This des cription contains the necessary information for the correct application of the product described below. It is intended for use
by technically qualified personal.
Safety Instructions
The following instructions are provided for the personal safety of operators and also for the protection of the described product and
connected equipment.
Warning!
Hazardous Voltage.
Failure to observe can kill, cause serious injury or damage.
•
Isolate from mains before installation or dismantling work, as well as for fuse changes or post installation modifications.
•
Observe the prescribed accident prevention and safety rules for the specific application.
•
Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage.
•
Emergency stop devices must be provided for all applications. Opearation of the emergency stop must inhibit any further
uncontrolled operation.
•
The electric connections must be covered!
•
Earth connection must be checked for safe function after assembly!
Connection draw ing and Settings
The switch-over of the mechanical vibrating frequency and the effect of the control input inhibit/enable are realised with the jumpers
S1 and S2. To do this, it is necessary to remove the left side cheek of the enclosure.
Attention!
This input is at mains potential!
Adjustment:
•
Connect controller according to diagram.
•
Adjust setpoint to minimum and inhibit unit.
•
Switch on mains supply and enable unit.
•
Slowly increase the setpoint to maximum and monitor
the load condition (if possible measure the voltage and current).
•
On reaching maximum, limit the output with trimmer
U
max
and then set the minimum set point value with
trimmer U
min
.
!
!
Change-over vibrating frequency
Change-over Inhibit/Enable
3000 / min (50Hz)
6000 / min (100Hz)
Enable
Inhibit
Power ON
Power OFF
1
S1
S2
1 2
1 2
24V /
24V /
Power ON
Power OFF
-
+
Inhibit
24V
Setpoint
10K Ohm
A
S
E
1
Umax
Umin
REOVIB 506
2
3
4
5
8
9
10
230V, 50/60Hz
L
N
PE
Load
0
10 20 30 40 50 60 70 80 90 100 [%]
10
20
30
40
50
60
70
80
90
100
[%]
Output voltage
Set point
Umin
Umax
Adjustment range
Effects of the min. and max. trimmer
Only use Type FF 5A semiconductor
fuses as replacement!
1
Umax
Umin
2
3
4
5
A
S
E
10K Ohm
Control cables should be laid separate
from other cables or should be screened.
Inhibit/Enable using signal
voltage 12...24 V, DC
Inhibit/Enable using
contact
ELEKTRONIK