REO REOVIB 506 Скачать руководство пользователя страница 1

Operating Instructions  

REOVIB 506 

 

ID Nr. 50606

 

 

REO-USA, Inc.     

 

 

 

 

 

 

 

 

Publication No. 

50606GB.Anl 

 

   

 

 

 

 

 

 

 

 

 

 

04.98

 

 

 

Thyristor control unit for use with vibratory feeder units

 

 
The REOVIB 506 range of control units are suitable for powering vibratory feeders which have a mechanical vibrating frequency 
which is the same as, or double that of mains frequency. The adjustment of feeder throughput is achieved by using a triac with 
phase angle control. The setpoint for the feeder throughput can be derived from a potentiometer. The set point range can be 
adjusted to suit the feeder unit by using trimmers (see “effects of trimmers Umin/Umax“). 
The units can operate with feeders which have a mechanical vibrating frequency 50 Hz or 100 Hz, ie 3000/6000 vibs/min (for 60 Hz 
mains supply this would be 60 Hz or 100 Hz, ie 3600/7200 vibs/min). The vibrating frequency is determined internally. An enable 
input is provided on terminals 1 and 2 for power free switching of the output (eg from a PLC).  
To prevent surges when the unit is switched on, a soft starter is provided. This sof starter becomes effectif with all switchings 
(mains “ON“, enable “ON“) and with set point adjustment. The semiconductors are protected against short -circuit current by an 
internal short-circuit fuse. 
The output voltage of the unit is fed back internally and compared with the adjusted set point in a regulating device. Deviations 
which may be caused by mains variations or load changes are adjusted correspondingly. 
The unit is supplied in a simple to install modular housing which is suitable for DIN rail mounting (EN 50022-35). The terminals have 
safety covers, according to VBG 4 standards. 
 

Technical data

 

 

 

Specified Use  

 

The units described herein are electrical controllers for installation in industrial plant.  
They are designed for power adjustment to resistive and inductive loads.

 

 

 

Dimensions drawing 

 

 

Ordering code: 

REOVIB 506 

ID-No. 50606

 

Type REOVIB 506 

50606 

Supply voltage 

230 V, + 6 % / - 10 %, 50/60 Hz 

Output voltage 

0 ... 220 V 

Output current 

0,5 ... 2 A 

Frequency 

3000/6000 vibs./min (switchable) 

Set point source 

Potentiometer 10 k

 

Enable input 

Contact / 12...24 V, DC signal voltage Ri 10 k

 

Ambient operating temperature 

0...45 °C 

Dimensions (h x w x d) 

74 x 45 x 125 mm 

Protection 

IP 00 

Other standards 

IEC 801-2, IEC 801-4, EN 50081-1, VBG 4 

 

1

Umax

Umin

REOVIB 506

2

3

4

5

8

9

10

45

74

100

125

ELEKTRONIK

 