20
Load Terminal
Programming the Load Terminal
Battery Type
System Voltage
Make sure the load is compatible with the battery type
of the system. 12V loads damaged in 24V battery
systems will not be covered in warranty.
The Load Terminal allows you to connect DC devices directly to
the controller with timer functions as optional features. The Load
Terminal is an extension of your battery charging circuit so the
voltages on your battery will be present in the Load terminal
since it is powered by the battery. This means that when
charging a 12V bank, those charging voltages will also be seen
in the Load Terminal. The terminal limits are set by the controller,
so no more than 10Amps. In addition, when connecting to a 24V
battery bank, you will also have a 24V DC Load Terminal that you
can also utilize. Stick with simple electronics such as lights, fans,
that have no issues turning on/off at any time.