Powering Appliances
COMMUNICA
TION
AC OUTPUT
20A
SOLAR INPUT
2
+
+
EXPANSION
4.2.4
4.2.5
I/ON
O/OFF
I/ON
O/OFF
AC OUTPUT
20A
AC INPUT
20A
AC/INV
SET
UP
DOWN
ENT
CHARGE
FAULT
SOLAR
1
SOLAR
2
BATTER
Y
SURCE
AC OUTPU
T 20A
AC OUTPU
T 30A
AC OUTPU
T 30A
PROTEC
TION
BLUET
OOTH
POWER
LINK
BT-2
Bluetoot
h Module
4.2.6
Plug the Adapter Cable into
the 30A AC Outlet of the
LYCAN.
Replace the cover to the
AC Load Center. Push the
switches on all the AC Circuit
Breakers toward the center of
the AC Load Center.
Loosen the captive screws to
open the Viewing Window.
AC OUTPUT 20A
AC OUTPUT 30A
AC INPUT
4.2.7
CHARGE
FAULT
ENT
DOWN
UP
SET
AC/INV
CHARGING
LI
INPUT
100%
25%
CHARGE
FAULT
ENT
DOWN
UP
SET
AC/INV
CHARGING
LI
INPUT
BYPASS
100%
25%
4.2.8
Powered by Bypass AC
Powered by Batteries
Push the switch on the 30A
AC Output Circuit Breaker up.
The Solar Inverter Charger AC/INV Indicator lights up yellow
when the appliances are powered by bypass AC.
The Solar Inverter Charger AC/INV Indicator flashes yellow when
the appliances are powered by the batteries.
z
Please close the Viewing Window and tighten the captive screws after completing the steps
above.
z
The AC Circuit Breakers and the appliances MUST be rated at 120VAC.
z
The continuous loads shall not exceed 24A, and the noncontinuous loads shall not exceed 30A.
z
If the appliances are powered by bypass AC from a 20A outlet, the continuous loads shall not
exceed 16A, and the noncontinuous loads shall not exceed 20A.
z
If the appliances are powered by bypass AC from a 15A outlet, the continuous loads shall not
exceed 12A, and the noncontinuous loads shall not exceed 15A.
Temporary Power Supply
Off-Grid Living
Emergency Backup