![Renogy DCC-1212 Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/renogy/dcc-1212-series/dcc-1212-series_manual_1442873010.webp)
Caution: The DCDC will turn on when the ignition is on. This means that even if your engine is
not on, the starter battery will immediately be used to power the DCDC and start charging the
house battery. It is recommended to have the vehicle completely on.
IMPORTANT: A D+ ignition cable is required to turn the unit on. Although the D+ terminal is
in the output side, this will be connected to the INPUT Alternator/Starter Battery.
Figure 5
Operation
When the input and output batteries as well as the signal wire is connected, the DCDC will power on
with green LED.
IMPORTANT: The DCDC will not turn on without a D+ ignition cable.
LED Indicator
Color, Behavior
Status
Description
Off
No Load
Unit is off; If abnormal, see
troubleshooting for more detail.
Green
Operation Normal
Red
Fault
There is an error in your system,
see troubleshooting for more
detail
18-16AWG, copper