• Place a wrench SW 12 onto the square counter bearing
(2.1)
to move the shaft of the machine down
till the holes of the upper adapter
(3.7)
line up with the connecting rod of the crimping unit.
• Connect the adapter intake and the connecting rod with the locking pin
(3.8)
.
• Secure crimping unit with the clamping screw 2,5 mm
(3.13)
in the lower adapter.
• Fasten the shaft cover on both sides with an Allen wrench SW (size of wrench) 2,0
(3.9)
.
• Connect the air supply and open the shut-off valve
(2.2)
. The machine is now ready to use.
8.2.2 Disassembly and Assembly Ferrule Crimping Units
The ferrule crimping unit will adjust automatically to the appropriate ferrule size. For an optimal crimping
result the ferrule must be matched with the correct cable cross section. The exchange of ferrule crimping
units is done as follows:
Disassembly:
• The machine is in the base position.
• Close the shut-off valve
(2.2)
, disconnect the air supply, and then open the shut-off valve
(2.2)
(Note: When the shut-off valve is in the open position, the hand lever is in a horizontal position!).
• Release the remaining air by pressing the RESET button
(2.8)
.
• Loosen the clamping screws
(4.8)
of the shaft cover with an Allen wrench SW 3,0 and lift the shaft
cover
(4.7)
to the front to remove it.
• Remove the locking pin
(
4.6)
from the shaft with an appropriate tool, i.e. a pin punch.
• Loosen the clamping screw
(4.4)
with an Allen wrench SW 2,5 and pull the ferrule crimping unit out of
the adapter intake in the direction of the arrow.
Assembly:
• Push the ferrule crimping unit into the lower adapter up to the stop pin
(4.3)
.
• Place a wrench SW 12 onto the square counter bearing
(2.1)
to move the shaft of the machine down
till the holes of the upper adapter
(4.5)
line up with the connecting rod of the crimping unit.
• Connect the adapter intake and the connecting rod with the locking pin
(4.6)
.
• Secure crimping unit with the clamping screw 2,5 mm
(4.4)
in the lower adapter
• Place a wrench SW 12 onto the square counter bearing
(2.1)
and move the wrench all the way up to
the stop.
• Place shaft cover
(4.7)
back onto the machine and fasten the clamping screw 3,0 mm
(4.8)
lightly.
• Move the wrench on the counter bearing
(2.1)
all the way down until the crimping dies of the crimp unit
are completely closed.
• Fasten the shaft cover
(4.7)
with clamping screw 3,0 mm
(4.8)
.
• Reconnect the air supply and open the shut-off valve
(2.2)
. The machine is now ready to use.
Before connecting the crimp machine CM 25-3.4 to the air supply line, be sure to remove
the wrench from the square counter bearing.
Attention