a) Time Settings
Time settings for alarm duration and alarm delay at unauthorised entry or exit are made on the PCBs in
the alarm system casing using the DIP switches marked “T1”, “T2” and “T3” by setting them as follows:
DIP-switch “T1”: Exit delay:
Alarm trigger delay can be set between 15 seconds and 4 minutes (only alarm
zones Z1 and Z2)
Jumper position
Time
OFF
OFF
OFF
15 seconds
OFF
OFF
ON
30 seconds
OFF
ON
OFF
45 seconds
OFF
ON
ON
60 seconds
ON
OFF
OFF
90 seconds
ON
OFF
ON
2 minutes
ON
ON
OFF
3 minutes
ON
ON
ON
4 minutes
DIP-switch “T2” entry delay:
Alarm trigger delay can be set between 15 seconds and 4 minutes (only alarm
zone Z1)
Jumper position
Time
OFF
OFF
OFF
15 seconds
OFF
OFF
ON
30 seconds
OFF
ON
OFF
45 seconds
OFF
ON
ON
60 seconds
ON
OFF
OFF
90 seconds
ON
OFF
ON
2 minutes
ON
ON
OFF
3 minutes
ON
ON
ON
4 minutes