background image

Operation

•  First switch off the drill and disconnect it from the mains voltage.
•  Attach suitable hose connectors (not included) to the inlet and outlet of the pump and then attach the 

hoses to them. Make sure the connections are airtight. Secure the hoses against slipping out. Use only 

suitable hoses (suction hose on the suction side, pressure hose on the outlet side of the pump; observe 

the flow direction markings on the pump).

•  Open the drill chuck of the drill and clamp the drive shaft of the pump into it.

  Secure the pump and the drill against twisting or banging around, otherwise there is a high risk of 

injury!

  Water contact with the drill, its power cord or mains plug must be prevented at all times, as this 

may cause fatal electric shock! 

Operation

•  Put the end of the suction hose in the water to be pumped, making sure that no dirt can be sucked in. Put 

the hose on the outlet side e.g. in a suitable container. Secure the hoses so that they do not slip.

•  Open the shut-off valves, if any.
•  Switch the drill to clockwise rotation; switch off any striking mechanism.
•  Plug the drill to the mains voltage.

  Secure the pump and the drill against twisting or banging around, otherwise there is a high risk of 

injury!

•  Now switch on the drill and allow it to run at high speed (max. 2800 RPM). The pump is self-priming. If 

water is not pumped within 10-15 seconds, switch off the drill. Check the flow direction; pay attention to 

the markings on the pump.

•  When water is being pumped, the water flow rate can be regulated by changing the speed of the drill.
•  If all water has been pumped out, e.g. from the aquarium, switch off the drill immediately.

Removing from service

•  Switch off the drill and disconnect it from the mains voltage.
•  Open the drill chuck of the drill used and disconnect the pump from the drill.
•  Remove the hoses connected to the pump.
•  Dry off the pump and store it in a dry, frost-free place out of the reach of children.

Cleaning

The pump has no user serviceable parts, so never open or dismantle it. Maintenance, repair and associated 

pump dismantling may only be carried out by a specialist or a specialist workshop.
Use a dry, clean, soft and lint-free cloth to clean the pump. 

  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may dam

-

age the housing or prevent the product from functioning properly. 

Disposal

  At the end of its service life, dispose of the product according to the relevant statutory regulations.

Technical data

Drive shaft diameter .............................6 mm
Max. permissible speed ........................2800 RPM
Max. flow rate .......................................900 l/h
Self-priming ..........................................yes
Dry run protection .................................no
Suction height .......................................max. 1 m
Pump head ...........................................max. 2.5 m
Pumped medium ..................................clear, clean fresh water
Pumped medium temperature ..............max. +35 °C
Hose connection ...................................19.05 mm (3/4")
Recommended hose diameter .............15 mm
Dimensions (L x W x H) ........................110 x 73 x 70 mm
Weight ..................................................approx. 140 g

 Operating instructions

Drill pump

Item no. 2302374

Intended use

The drill pump (hereinafter referred to as “pump”) is intended for private use, e.g. in the hobby garden. Only 

clear, clean fresh water is allowed as the pumped liquid. The temperature of the pumped liquid must not 

35 °C.
The pump is designed to empty/fill small containers (e.g. aquariums, barrels) or to pump water out of defec

-

tive devices (e.g. washing machines). The pump must be driven by a conventional mains-operated drill with 

quick-action chuck.
For safety reasons, you must not modify and/or change the pump. The pump may be damaged if you use it 

for purposes other than those described above. Read the operating instructions carefully and store them in a 

safe place. The pump should be passed to third parties only with its operating instructions.
This product complies with statutory national and European regulations. All company and product names 

contained herein are trademarks of their respective owners. All rights reserved.

Delivery content

•  Drill pump
•  Operating instructions

Up-to-date operating instructions           

Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. 

Follow the instructions on the website.

Description of symbols

  The symbol with the lightning in a triangle indicates that there is a risk to your health, e.g. due to 

an electric shock.

  The symbol with an exclamation mark in a triangle is used to highlight important information in 

these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and tips on how to use the product.

Safety information

Read the operating instructions carefully and observe in particular the safety instructions. 

If you do not follow the safety information and information on proper handling in these 

operating instructions, we will assume no liability for any resulting personal injury or dam-

age to property. Such cases will invalidate the warranty/guarantee.

•  The pump is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. It may become a dangerous toy for 

children.

•  Protect  the  pump  from  extreme  temperatures,  direct  sunlight,  strong  vibrations,  flammable 

gases, vapours and solvents. Do not expose the pump to mechanical stress.

•  Handle the pump with care. It can be damaged by blows, impacts or if it falls from a small height.
•  Only clear, clean fresh water with a maximum temperature of +35 °C is allowed as the pumped 

liquid. The pump is not suitable for conveying drinking water, corrosive/caustic, flammable or 

explosive liquids (e.g. petrol, heating oil, cellulose thinner), fats, oils, salt water or waste water 

from toilet facilities.

•  The pump is not protected against dry running.
•  The pump must not be operated unsupervised and it is not intended for continuous operation.
•  Do not block off the suction/discharge side of the pump.
•  Check the pump for damage before each start-up; the same applies to the drill that is used to 

drive the pump. Do not use the pump if you discover any damage. 

•  If water leaks in the pump area during the pumping process, stop the pump immediately. Water 

contact with the drill, its power cord or mains plug must be prevented at all times, as this may 

cause fatal electric shock! 
Otherwise, disconnect the mains socket to which the drill is connected on all poles (unscrew the 

fuse or switch off the circuit breaker, switch off the ground fault circuit interrupter). Then unplug 

the drill from the mains socket and do not use it anymore!

•  When the pumping process is over (or during breaks at work), disconnect the drill from the 

mains voltage by pulling the mains plug out of the mains socket.

•  In the place of operation the ambient temperature must not be around or under the freezing 

point (<0 °C). Otherwise, the water in the pump will freeze, with the resulting ice build-up caus

-

ing the pump to destruct. Store the pump in a dry, frost-free place in wintertime.

•  Also observe the safety information and operating instructions for the other devices to which 

the pump is connected.

•  If you have questions which remain unanswered by these operating instructions, contact our 

technical support service or other technical personnel.

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in 

electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 

This publication represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE. 

  

*2302374_V1_1120_02_VTP_m_en

Отзывы: