23
12. Disposal
Electronic devices are recyclable and should not be disposed of in household waste. Dispose of the prod-
uct according to the applicable statutory provisions at the end of its service life.
13. Technical Data
Operating voltage .............................................230 V/AC, 50 Hz
Protection class ................................................I
Protection type ..................................................IPX8
Nominal power (P1) ..........................................250 W
Output power (P2) ............................................150 W
Self-priming ......................................................no
Overtemperature protection ..............................yes
Running-dry protection .....................................no
Connection cable ..............................................
H05RN-F, 3G0.75 mm², length approx. 10 m
Immersion depth ...............................................
max. 7 m
Conveying height ..............................................
max. 6 m
Conveyed volume .............................................
max. 6000 l/h (depending on the conveyed height)
Conveyor medium ............................................Clear, clean fresh water
Grain size/contamination ..................................
max. 5 mm
Conveyor agent temperature ............................
max. +35 °C
Hose connection ...............................................25,4 mm (1“) or 31,75 mm (1 1/4“)
Dimensions (L x W x H)
....................................
158 x 163 x 283 mm
Weight ..............................................................
approx. 3.66 kg (incl. cable)