Renishaw TONiC diagnostic kit Скачать руководство пользователя страница 8

TONiC diagnostic kit

User guide 

6

3.1. Connecting the system

Choose the appropriate interconnect cabling for your system from the options below and connect the TONiC readhead to the dongle. 

3.1.1. TONiC with a digital Ti interface (Ti0004 - Ti4000)

  Items required for connection:

 •

  Item 1, dongle 

 

  Item 3, USB cable

 

Connect  the TONiC readhead to the Ti interface. See the relevant TONiC installation guide for details of connecting the  
readhead to the Ti interface (System connection).

   Connect the output of the Ti interface to the input of the dongle

  If using the diagnostic dongle ‘in-line’ connect the output of the dongle to the customers’ controller

  Proceed to section 3.2. 

(‘3.2. Starting the software’, page 7)

 

TONiC

User guide 

Item 1

3.1.2. TONiC with digital Ti interface (Ti10KD or Ti20KD) or analogue Ti interface (Ti0000)
NOTE: 

Ti0000, Ti10KD and Ti20KD are not compatible with the diagnostic dongle so the system should be connected using the 

dongle interface

  Items required for connection:

 

  Item 6, sacrificial interconnect PCB for TONiC or ATOM cabled readheads.

 

  Item 5, Interface cable for  TONiC or ATOM readheads.

 

  Item 2, dongle interface.

 

  Item 1, dongle.

 

  Item 3, USB cable.

  Do not connect the readhead to the interface.

  Connect the sacrificial interconnect PCB to the JST connector on the interface cable (Item 5).

  Connect the mini PCB on the cabled TONiC readhead to the sacrificial interconnect PCB for cabled readheads (Item 6).

 

Ensure correct orientation of the connector, both cables will come out of the same side of the pcb.

  Open the cover plate on the dongle interface (Item 2) and connect the mini PCB into the interface.

 

See the relevant TONiC installation guide for details of connecting the readhead to the dongle interface (System connection).

  Connect the output of the dongle interface to the input of the dongle (Item 1).

  Proceed to section 3.2 

(‘3.2. Starting the software’, page 7)

 

 NOTE: 

The dongle interface/Ti interface connector is not designed for multiple insertions and removals.

 

The sacrificial interconnect PCB’s should be used and replaced when worn or damaged. 

Item 6

Item 5

Item 2

Item 1

Readhead

Interface

Section

TONiC

Ti0004 - Ti4000

3.1.1.

TONiC

Ti0000

Ti10KD
Ti20KD

3.1.2.

Содержание TONiC diagnostic kit

Страница 1: ...User guide M 9589 9081 02 A TONiC diagnostic kit...

Страница 2: ...tal Ti interface Ti0004 Ti4000 6 3 1 2 TONiC with digital Ti interface Ti10KD or Ti20KD or analogue Ti interface Ti0000 6 3 2 Starting the software 7 3 3 Using the software 8 3 3 1 Signal size 8 3 3 2...

Страница 3: ...MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION ALL WARRANTIES CONDITIONS REPRESENTATIONS AND LIABILITY HOWSOEVER ARISING ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW RENISHAW RESERVES THE...

Страница 4: ...be used with the unit to ensure compliance Further information Further information relating to the TONiC encoder range can be found in the TONiC system Data sheet and Installation guides These can be...

Страница 5: ...ld be used and replaced when worn or damaged Packs of 10 replacement PCB s are available to order Item 6 A 9411 0016 Item 7 A 9411 0017 Item Description Quantity 1 Dongle 1 2 Dongle interface 1 3 USB...

Страница 6: ...rface dimensions 1 5 Dongle dimensions Dimensions and tolerances in mm 62 33 3 12 5 33 3 39 Communication LED USB port 1 7 Signals Dongle interface Dongle Function Signal Output pin male 15 way D type...

Страница 7: ...the screen and the installation program will automatically run through the installation process NOTE On Windows 8 it will ask Do you want to allow the following program from an unknown publisher to m...

Страница 8: ...6 sacrificial interconnect PCB for TONiC or ATOM cabled readheads Item 5 Interface cable for TONiC or ATOM readheads Item 2 dongle interface Item 1 dongle Item 3 USB cable Do not connect the readhead...

Страница 9: ...USB port to the PC See 3 1 Connecting the system page 6 for details on connecting the TONiC readhead to the dongle The Start page will then become active The PSU voltage will display USB showing it i...

Страница 10: ...nal is activated The tone gets higher as the signal level increases NOTE When the TONiC dongle is connected the diagnostic LED on the dongle interface or Ti interface will flash orange it will not dis...

Страница 11: ...t of bar not within the boxes TONiC User guide 3 3 3 Pitch indicator The pitch of the readhead is displayed as a spirit level To ensure the correct pitch the bubble should be positioned between the tw...

Страница 12: ...he readhead starts double flashing Move the readhead backwards and forwards across the chosen reference mark The CAL button will turn grey and the signal size and reference mark displays will be react...

Страница 13: ...used between the readhead and the dongle interface 3 1 Connecting the system page 6 The dongle must be used with the dongle interface unless using a Ti0004 Ti4000 Check connections between the dongle...

Страница 14: ...pressing and holding the CAL button on the dongle interface whilst cycling the power See the relevant TONiC installation guide for details of the calibration routine and restoring factory defaults 4...

Страница 15: ...eady to use 5 2 Manual hardware driver installation If the drivers have not automatically installed they can be manually installed Browse C Program files x86 Renishaw TONiC diagnostic Depending upon i...

Страница 16: ...0 1453 524901 E uk renishaw com www renishaw com For worldwide contact details visit www renishaw com contact Part no M 9589 9081 02 A Issued 02 2021 M 9589 9081 02 Renishaw plc Registered in England...

Отзывы: