Step 3: Re-fit screw locks through facia panel, 
but do not fully tighten. 

Screw locks (4 off)

Step 4: Fit 4 off screws but do not fully tighten.

Screw A (4 off)

Step 5: Slacken screws B by 1/4 or 1/2 turn. 
Complete final tightening sequence:
1) Tighten 4 off screw A (identified in Step 4)
2) Tighten 2 off screw B (identified in Step 5)
3) Tighten screw locks (identified in Step 3)

Screw B (2 off)

Full details of the RPI20 parallel interface can 
be found in data sheet L-9904-2352.  For a copy 
visit www.renishaw.com or contact your local 
Renishaw office.

© 2006 Renishaw plc.  All rights reserved. 

Printed in England 0306 Part No. M-9904-2375-02

Renishaw reserves the right to change specifications 

without notice.

For worldwide contact details, please visit 
our main website at:
www.renishaw.com/contact

Facia panel