![Renishaw PI 7-2 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/renishaw/pi-7-2/pi-7-2_installation-manual_1441466012.webp)
0
Product description
Configuration switches
Switch
no.
Function
Position Description
1
SSR invert
UP
DOWN
SSR closed when probe seated
SSR open when probe seated
2
Buzzer
UP
DOWN
Audible indication of probe trigger - OFF
Audible indication of probe trigger - ON
3
Kinematic probe
input
UP
DOWN
Autojoint input only
PICS input enabled
4
Probe type
UP
DOWN
Optimise for issue ‘01’ (or later) probe
All probe types
5
STOP disable
UP
DOWN
No response to PICS - STOP
Trigger outputs respond to PICS - STOP
6
HALT invert
UP
DOWN
PICS - HALT output active HIGH
PICS - HALT output active LOW
7
HALT mode
UP
DOWN
HALT generated internally
HALT asserted by PICS
8
Auto reset
DOWN
UP
Automatic reset disabled
Probe will reset after 2 seconds
9
Trigger
sensitivity
DOWN
UP
Level 1 (high sensitivity)
Level 2 (mid sensitivity)
10
No function - unused
Switch
The solid state relay (SSR) output contacts may be set to be open when the probe is
seated and closed when the probe is triggered. The output may be inverted to mimic
the action of a kinematic probe.
Switch 2
The internal audible indicator normally gives a short tone burst when the SYNC output
changes from the seated to the triggered state. The switch may be set to enable or
disable the sound.