- 6 -
EN
Problem
Cause
Remedy
Fuse triggers.
• Load of the connected
extractor too high,
adhere to the max.
connected load (see
technical data).
• Connect the extractor separately to the
electricity supply.
Reduced remov-
al or application
of greater pres-
sure required.
• Cutter blunt
• Change the cutter (see Section 2.5).
Cutter slips out
during opera-
tion.
• Cutter not inserted far
enough into the clamp-
ing ring.
• Clamping ring not
tightened enough.
• Insert the cutter fully into the clamping
ring.
• Tighten the clamping ring further.
Cutter cannot
be inserted.
• Original Renfert cutter
not used.
• Always use original Renfert cutters.
Cutter cannot
be removed.
• Clamping screw not
loosened enough.
• Corrosion on the cutter
shank.
• Loosen the clamping screw further.
• Return the unit for repair.
Clamping screw
cannot be loos-
ened.
• Screw overtightened.
• Return the unit for repair.
Connected ex-
tractor does not
operate.
• Extractor not switched
on.
• Extractor is in automat-
ic operation mode.
• No electricity supply to
the plug-in socket.
• Switch on the extractor.
• Set the extractor to continuous
operation.
• Return the unit for repair.