background image

- 15 -

EN

5.2 Condensation

1.  Inspect the water separator.

2.  Drain any water off through the valve (Fig. 21).

5.3 Blasting Nozzle 

Replacement

1.  Refer to insert no. 21-9162 for installation.

2.  Inspect for abrasive residue.

3.  Inspect the seal ring position.

5.4  View Port Replacement

Please refer to the installation instructions provided 
with the new pane (insert no. 21-9811).

5.5 Sandblasting Hose 

Replacement

1.  Disconnect the sandblasting unit from the com-

pressed air supply (Fig. 4,3,2).

2.  Refer to insert no. 21-9162 for the installation 

instructions.

5.6  Replacing the Fluorescent 

Lamp

 Danger of breakage! 

Do not press on the fluorescent lamp or try 
to bend it when replacing it. We recommend 
using gloves or a cloth to protect your hands 
in case of breakage.

•  Switch off the unit.

•  Pull plug out.

•  Lightly press light cover on the right side and 

remove it (Fig. 7).

•  Pull fluorescent lamp horizontally out of the socket 

and remove it.

•  Vacuum socket as thoroughly as possible.

•  Insert new fluorescent lamp in the retainer and 

slide it horizontally into the socket (Fig. 8).

•  Install lamp cover in the housing on the left side, 

then press it to the right until it clicks into position 
(Fig. 9).

 Use only original Renfert replacement fluore-

scent lamps (see spare parts list).

5.7  Replacing the lamp cover

•  Switch off the unit.

•  Pull plug out.

•  Lightly press lamp cover on the right side and 

remove it (Fig. 7).

•  Install lamp cover in the housing on the left side, 

then press it to the right until it clicks into position 
(Fig. 9)

6. Spare Parts

For the order numbers of consumables and spare 
parts please refer to the spare parts list at the end of 
this manual.

7. Warranty

Provided the unit is properly used, Renfert warrants 
all parts of the 

Basic master 

for a 

period of 3 years

In case of any claims for warranty original dealers‘ 
invoice is required. Components subject to natural 
wear (e.g., blasting nozzles, hoses, fluorescent tubes, 
hose connections, view panes, filter materials, etc.) 
are excluded from this warranty. The warranty is 
voided in case of improper use; failure to observe the 
operating, cleaning, maintenance, and connection 
instructions; in case of independent repairs or repairs 
by unauthorized personnel; if spare parts from other 
manufacturers are employed, or; in case of unusual 
influences or influences not in compliance with the 
utilization instructions. Warranty service shall not 
extend the original warranty.

8. Technical Specifications

Working pressure:  

1 - 6 bar [14,5 - 87 psi]

Connecting pressure, external:  6 - 8 bar [87 - 116 psi]
Air consumption:  

120 l/min. at 6 bar [87 psi]

Voltage: 

230 V, 50/60 Hz 

 

100-120 V, 50/60 Hz

Lamp power consumption: 

16 W 

Cable length: 

2 m [78,74 inch]

Ø hose connection:  

interior: 4 mm [0,16 inch] 

 

exterior: 6 mm [0,24 inch]

Ø size of pipe union for external extraction unit: 
 

interior: 35 mm [1,38 inch] 

 

exterior: 40 mm [1,58 inch]

Dimensions (WxHxD):  

400 x 285 x 400 mm 

 

[15.76 x 11.23 x 15.76 inch]

Blasting chamber volume:  

18 l

Tank capacity: 

1000 ml each

Weight (empty):  

approx. 7 kg

Noise level according to DIN 45635-01-KL3: 
 

< 72 dB(A)

9. Blasting Notes

Flat blasting with wide nozzles:
No. 90002-1207  0.3 x 3.5 mm [0.012 x 0.138 inch]
No. 90003-1739  1.5 x 3.5 mm [0.059 x 0.138 inch]
When blasting glass ceramics, refer to manu facturer‘s 
notes.

Содержание 2946

Страница 1: ...FEJFOVOHTBOMFJUVOH OTUSVDUJPO NBOVBM PEF EtFNQMPJ TUSV JPOJ E VTP OTUSVDDJPOFT QBSB FM TFSWJDJP Made in Germany Basic master Nr 2946 0310 21 6572 A Ideas for dental technology...

Страница 2: ...H BSF TIPXO PO UIF UZQF QMBUF PG UIF VOJU F OVN SP EF T SJF FU MB EBUF EF GBCSJDBUJPO TF USPVWFOU TVS MB QMBRVF TJHOBM UJRVF EF M BQQBSFJM M OVNFSP EJ TFSJF F MB EBUB DPTUSV JPOF TJ USPWBOP TVMMB UBSH...

Страница 3: ...1 2 3 4 5 6 7 8...

Страница 4: ...9 11 10 12 13 14 15 16...

Страница 5: ...17 18 19 20 21...

Страница 6: ...cal hazard There is a risk of electrical shock Attention Failure to observe the associated informa tion can result in damage to the unit Note The operating instructions contain useful information to m...

Страница 7: ...the screw on coupling over the supplied blue compressed air hose Fig 3 5 Connect the compressed air hose to the unit and tighten the coupling sleeve Fig 4a 6 Connect the compressed air hose to the co...

Страница 8: ...s For the order numbers of consumables and spare parts please refer to the spare parts list at the end of this manual 7 Warranty Provided the unit is properly used Renfert warrants all parts of the Ba...

Страница 9: ...cling Within the European Union units with this symbol should not therefore be disposed of in unsorted do mestic waste For more information regarding proper disposal please apply at your local authori...

Страница 10: ...ate the foot switch repeatedly in succession Before re lling with sand check the tank and sandblasting material for contamination or moisture If necessary replace with new sand Re ll with sand and sec...

Страница 11: ...ist Refer to Sec 5 6 Fluorescent Lamp Installation Compressed air leaking from the foot switch Pneumatic hoses re versed Reverse the connections Foot switch fails to switch on No pressure at the com p...

Отзывы: