13. Troubleshooting Guide

Problem

Possible cause

Corrective action

No air and no abrasive.

•  Blasting nozzle blocked at the 

hand-piece.

 

•  Foot switch connecting lines 

kinked.

•  Unscrew the nozzle from the hand-piece and 

blow it out.

•  With the nozzle removed, blow out the blasting 

hose by activating the foot pedal.

•  Inspect/correct the connection lines.

Only air, no or very 

little abrasive.

•  The dosage nozzle in the mix-

ing chamber is blocked due to 

contaminated or moist sand.

•  Mixing chamber filter combination 

blocked.

•  Abrasive contains impurities or is 

moist.

•  Cleaning the dosing nozzle, see chapter 5.4. 

 

•  Change filter cartridge (Wrench SW14).

 

•  Replace the abrasive.

Unit blasts continu-

ously.

•  Foot switch connected incorrectly.

•  Valve in foot switch is defective.

•  Inspect / correct the foot switch connection.

•  Replace foot switch.

Compressed air 

leaking from the foot 

switch.

•  Pneumatic hoses reversed.

•  Reverse the connections.

Foot switch fails to 

switch on.

•  No pressure at the compressed 

air connection.

•  Pneumatic hoses are kinked.

•  Inspect the compressed air lines and/or the com-

pressor.

•  Reposition the hoses.

Subject to modification.

Содержание 2914

Страница 1: ...gsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones de servicio Инструкция по эксплуатации 取扱説明書 사용 설명서 Made in Germany Basic mobil Nr 2914 219093 03032016 B Ideas for dental technology ...

Страница 2: ...1 2a 2c 4 6 5 3 2b ...

Страница 3: ...7 9a 10 12 13 11 9b 8 ...

Страница 4: ...14 ...

Страница 5: ...raction should be selected on the basis of the dust being generated Follow here absolutely EN 60335 2 69 appendix AA or ask the appropriate authorities Improper use can result in the risk of eye or skin injuries Never direct the blasting material towards eyes or unprotected areas of skin Caution Failure to wear proper eye protection can result in eye injury due to particles suspended in the air Al...

Страница 6: ...The sandblasting unit is now operational 5 Cleaning Maintenance Use only solvent free cleansers e g soapy water Wipe out the tanks and lids only with a dry cloth 5 1 Condensation 1 Inspect the water separator 2 Close the shut off valve Fig 11 3 Drain any water off through the valve Fig 12 employing the foot switch Fig 6 5 2 Blasting Nozzle Replacement 1 Refer to insert no 21 9162 for installation ...

Страница 7: ...acity 1000 ml 34 fl oz Weight empty approx 2 5 kg 5 5 lbs 9 Notes Flat blasting with sheet dies Art No 90002 1207 0 3 x 3 5 mm 0 012 x 0 138 inch Art No 90003 1739 1 5 x 3 5 mm 0 059 x 0 138 inch When blasting glass ceramics refer to manufac turer s notes 10 Standard Delivery 1 Basic mobil 1 Foot switch only with no 2914 3050 2914 3250 1 Connection set 1 Set of Operating Instructions with attachme...

Страница 8: ... or moist sand Mixing chamber filter combination blocked Abrasive contains impurities or is moist Cleaning the dosing nozzle see chapter 5 4 Change filter cartridge Wrench SW14 Replace the abrasive Unit blasts continu ously Foot switch connected incorrectly Valve in foot switch is defective Inspect correct the foot switch connection Replace foot switch Compressed air leaking from the foot switch P...

Страница 9: ...ert USA 3718 Illinois Avenue St Charles IL 60174 USA Tel 1 6307 62 18 03 Fax 1 6307 62 97 87 www renfert com richardj renfertusa com USA Free call 800 336 7422 Ideas for dental technology Hochaktuell und ausführlich auf Up to date and in detail at Actualisé et détaillé sous Aggiornato e dettagliato su La máxima actualidad y detalle en Актуально и подробно на www renfert com ...

Отзывы: