Fault
Cause
Solution
It is not possible to adjust
the drill length, as the
Allen key cannot be used.
• The hexagon socket is full of drilling
dust.
• Remove drill jig and chuck and use a pointed
instrument to remove the drilling dust from the
hexagon socket.
The unit does not switch
on.
• The sensor surface has been
touched too briefly or too lightly.
•
Place the palm of your hand onto the marked surface
for approximately 1 second. It is not necessary to use
any pressure.
The drilling depth
suddenly changes.
•
The drill bit is not sufficiently fixed
in place; it stops during drilling and
therefore alters the drill stop depth.
• The coating on the drill stop
(threaded pin) is worn out..
• Re-set the drill stop (see section 5.6); tighten the drill
jig by hand (without tools).
•
Insert replacement threaded pin (see last page of the
instructions for use).
The drill bit does not turn.
• The shaft diameter of the drill bit is
too small.
• Use a drill bit with the correct shaft diameter size (see
section 8 Technical Data).
Do not
turn the chuck further with tools!
The drilling is not
effective.
• The drill bit is worn.
• Replace the drill bit.
The drill holes are too big
or not round.
• The drill jig is not tight enough.
•
Tighten the jig by hand.
The unit switches off
abruptly and the
operation display blinks
briefly.
• The model was pushed too hard
into the drill bit.
•
Depress the drill table quickly but not suddenly.