HE-Series Indoor
ERV
CONFIGURATION CODE
HE1.5 MODEL
CONFIGURATION GUIDE
Note: Not all options are available on every model.
For Technical Support E-mail: [email protected]
To Place an Order E-mail: [email protected]
MODEL NUMBER
H E 1 . 5 J I N
-
- -
-
DIGIT NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Digit 9:
Orientation
Digit 19:
Unit Control (see Restriction 4)
"V", "H"
"A" = Standard Unit Control Wiring
"D" = Independent Blower Control
Digit 11:
Wall Type
"G" = Terminal Strip for EC Motors
"S" = Single
"D" = Double
Digit 20:
Disconnect
"N" = Non-Fused (Standard)
Digit 12:
Phase (See Restriction 3)
"F" = Fused
"1" = Single Phase
"3" = Three Phase
Digit 21:
Unit Control Enhancements (see Restriction 6)
"T" = Transformer with Isolation Relay (Standard)
Digit 13:
Voltage (see Restriction 1 & 2)
"1" = Enhanced Controls
"1" = 120V
"2" = Premium Controls
"4" = 460V
"3" = Enhanced Controls with BACnet License
"5" = 208-230V
"4" = Premium Controls with BACnet License
"9" = 277V
Digit 22:
Filter Options
Digits 14-15:
Motor Horsepower (See Restriction 3)
"-" = None (Standard)
"SS" = Standard Impellers
"F" = Filter Monitor Both Airstreams
"EE" = EC Impellers
Digit 23:
Other Options
Digit 18:
Flow Control*
"-" = None (Reserved)
"-" = No Isolation Dampers (with no Bypass)
"D" = Motorized Damper both Airstreams (with no Bypass)
Digit 24:
Paint and Customization
"E" = Motorized Damper EA Airstream (with no Bypass)
"-" = None
"F" = Motorized Damper FA Airstream (with no Bypass)
"W" = White Paint
"S" = Backdraft Damper OA Airstream (with no Bypass)
"C" = Custom Paint
"R" = Backdraft Damper EA Airstream (with no Bypass)
"X" = Custom Unit
"B" = Backdraft Damper both Airstreams (with no Bypass)
"T" = Motorized Damper OA, Backdraft Damper EA (with no Bypass)
Digit 25:
Safety Listing (see Restriction 5)
"0" = Dry Bulb Face and Bypass Dampers only
"L" = Listed
"1" = Dry Bulb Bypass with Motorized Dampers all Airstreams
"N" = Non-Listed
"4" = Dry Bulb Bypass with Backdraft Damper OA Airstream
"5" = Enthalpy Bypass Dampers only (no Isolation Dampers)
"6" = Enthalpy Bypass with Motorized Dampers all Airstreams
"9" = Enthalpy Bypass with Backdraft Damper OA Airstream
*NOTES:
Digit 6 "J" = G5 Core Type. Digits 10, 16, and 17 are not used in these models.
*Digit 18: Flow Control: Codes for Bypass: Face damper also acts as Isolation Damper in EA or RA Airstream.
Restrictions:
1: Voltage Codes "1" & "9" only available with Phase Code "1" (Single Phase).
2: Voltage Code "4" only available with Phase Code "3" (Three Phase).
3: Motor Codes "EE" (EC Motors) only available with Phase Code "1"(Single Phase).
4: Unit Control Code "G" (Terminal Strip) only available with Motor Codes "EE" (EC Motors).
5: Some units with Other Options Code "X" are not safety listed.
6: Unit Control "A" not available with Unit Control Enhancements Codes "1", "2", "3", & "4".
CONFIGURATION CODE