RX62T YROTATE-IT-RX62T Motor Control Kit
UM-YROTATE-IT-RX62T Rev.1.00
Page 50 of 51
Jan 15, 2014
Label(s)
Type
Description
Unit
vbus_ad
signed
short
A/D conversion result of the DC link voltage reading.
iss_off
signed
short
A/D conversion offsets of measured single shunt current; the
value is around 2048, that corresponds to one half of the A/D
converter supply voltage (5Vdc) (12bit A/D).
iaad, ibad
signed
short
A/D conversion result of the first and the second single shunt
current reading.
deadtim
unsigned
short
Dead-time.
MTU pulses
semiper
unsigned
short
PWM half period.
MTU pulses
semiperdead
unsigned
short
PWM half period plus dead-time.
MTU pulses
cr_ss
unsigned
short
Status variable for single shunt current reading.
trip_cnt
unsigned
short
Counter for estimation error detection.
startup_cnt
unsigned
short
Counter for startup.
startup_val
unsigned
short
Startup time.
N° of sampling
periods
stp_tim
unsigned
short
Startup time.
ms
XXXXXX_ep
unsigned
short
Many variables with suffix “_ep”: they are copies of various
parameters, used for EEPROM management.
enc_ind
unsigned
short
Index in encoder filter table.
enc_sam
unsigned
short
Encoder sample.
enc_ang
unsigned
short
Encoder angular position.
2PI is 65536
mec_ang
float
Mechanical position.
rad
ele_ang
float
Electrical angular position.
rad
off_ang
float
Electrical position offset.
rad