background image

 

Section 2   Connection Procedures 

2.1 

Connecting User System Interface Cable to Emulator Station 

WARNING

 

   

Observe the precautions listed below.  Failure to do so  

  will result in a FIRE HAZARD and will damage the user  
  system and the emulator product or will result in  
  PERSONAL INJURY.  The USER PROGRAM will be  
  LOST.   
  1.   Always switch OFF the user system and the emulator 
   

product before the USER SYSTEM INTERFACE CABLE  

   

is connected to or removed from any part.  Before  

   

connecting, make sure that pin 1 on both sides are  

   

correctly aligned.  

  2.  The user system interface cable dedicated to the  
   

emulator must be used.   

To connect the cable body to the emulator station, follow the instructions below. 

1.  Make sure the user system and emulator station are turned off. 

CAUTION 

   

When connecting or removing the user system interface 

  cable, apply force only in the direction suitable for 
  connection or removal, while making sure not to bend or 
  twist the cable or connectors. Otherwise, the connectors will 
 be damaged. 

2.  After making sure the direction of the cable body connector is correct, firmly insert the cable 

body connector into the emulator station socket (figure 2). 

Содержание User System Interface Cable HS2655ECH61H

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...H8S 2655 Group QFP 128 User System Interface Cable HS2655ECH61H User s Manual User s Manual Rev 4 0 2004 01 Renesas Microcomputer Development Environment System...

Страница 4: ...described here may contain technical inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or err...

Страница 5: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of c...

Страница 6: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Страница 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Страница 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Страница 9: ...r remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or P...

Страница 10: ...s original microcomputer H8S 2655 group The HS2655ECH61H is a user system interface cable that connects an H8S 2655 group E6000 emulator HS2655EPI61H hereinafter referred to as the emulator to the IC...

Страница 11: ...C Socket 6 2 2 2 Soldering IC Socket 7 2 2 3 Inserting Cable Head 7 2 2 4 Fastening Cable Head 8 2 2 5 Fastening Cable Body 10 2 3 Recommended Dimensions for User System Mount Pad 11 2 4 Dimensions fo...

Страница 12: ...TION Use an NQPACK128RD socket manufactured by Tokyo Eletech Corporation for the FP 128 package IC socket on the user system Figure 1 shows the configuration of the HS2655ECH61H user system interface...

Страница 13: ...2 Figure 1 HS2655ECH61H User System Interface Cable...

Страница 14: ...dy 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 128 package 4 Socket cover 1 For installing anFP 128 packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For instal...

Страница 15: ...make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructi...

Страница 16: ...5 Figure 2 Connecting User System Interface Cable to Emulator Station...

Страница 17: ...HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions bel...

Страница 18: ...the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 2 3 Inserting Cable Head CAUTION...

Страница 19: ...sed by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fas...

Страница 20: ...9 Figure 4 Connecting User System Interface Cable to User System...

Страница 21: ...10 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body...

Страница 22: ...m with an IC socket for an FP 128 package NQPACK128RD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad Un...

Страница 23: ...12 2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head...

Страница 24: ...Connecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Conne...

Страница 25: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Страница 26: ...15 User system Screws M2 x 6 mm IC socket Tokyo Eletech Corporation NQPACK128RD Socket cover MCU Pin 1 Figure 9 Installing MCU to User System...

Страница 27: ...clock an emulator internal clock and an external clock on the user system For details refer to the Emulator Supplementory Information HS2655EPI61HE To use the emulator internal clock Select the clock...

Страница 28: ...pecifically designed for the HS2655EPI61H emulator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on t...

Страница 29: ...18 6 The JP1 jumper socket is used for testing Do not remove the inserted jumper pin JP1 Figure 12 JP1 Jumper Socket...

Страница 30: ...nual Publication Date Rev 4 00 January 29 2004 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas Kodaira Semiconductor...

Страница 31: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan H8S 2655 Group QFP 128 User System Interface Cable REJ10B0086 0400H HS2655ECH61H User s Manual...

Отзывы: