Field
Option
Description
Test
Options
Production
tests
Enables /Disables the production test procedure. This is the same option as
Production
tests
Memory
programming
Enables /Disables the production test procedure. This is the same option as
Memory programming
VBAT/UART
Init
If this option is enabled, the PLT hardware will be reset before enabling the
DUTs. This option is enabled only when
VBAT/UART
in the main screen is
enabled.
DUTs
Bitwise DUT set/reset for each of the 16 DUTs using a 16-bit hexadecimal
value. 089
Example:
To enable only DUTs 1, 2, 15 and 16 use "C003" (1100 0000 0000
0011 = 0xC003).
UART check
Baud rate
Sets the Baud rate for the UART check test.
7.3.2
Running the GUI PLT and Executing Tests
The GUI PLT starts the test procedure when users click the
START
button. Before initiating the test
procedure, the GUI PLT will assign BD addresses to the active DUTs and check for any wrong
configuration parameters.
If
Run scripts before testing starts
is enabled, PLT will execute the selected script/executable,
and wait until it finishes or times out, depending on the selections made in Section
. If the
script/executable has returned on time, PLT will check the return code. Values from 0 to 100 indicate
a successful completion. Negative values or values larger than 100 indicate an error. In the case of
an error (either time out or error returned result), a pop-up message will appear indicating the return
code and the test procedure will not start.
Figure 75: GUI PLT - Erroneous Messages in
“Run Scripts Before Testing Starts”
If any OTP burning test is scheduled, a pop-up message will inform the user and prompt to continue
(
Figure 76: GUI PLT OTP Burn Warning Message