UM-B-041
SmartBond Production Line Tool
User Manual
Revision 4.8
02-Nov-2022
CFR0012
61 of 170
© 2022 Renesas Electronics
7.2.6.2
OTP Timestamp Read
Figure 45: OTP Timestamp Read
If this option is enabled, PLT will read the device timestamp from the OTP memory and log it. This
operation is mainly used for logging purposes.
7.2.6.3
XTAL Trim
Figure 46: XTAL Trim
describes the available options for the
XTAL Trim
operation.
Table 31: XTAL Trim
Option
Description
Enable
This option enables the automatic crystal oscillator frequency calibration procedure.
GPIO input pulse pin
The DUT GPIO to receive the reference pulse during calibration. UART RX pin can
be used without any additional connection from the PLT hardware to the DUT.
Figure 47: GPIO Watchdog Operation
describes the available options for the
GPIO Watchdog operation
.
Table 32: GPIO Watchdog Operation
Option
Description
Enable Watchdog
This option enables the continuous toggling of a GPIO during the whole production
testing and memory programming procedure, except during firmware download.
The pulse on the GPIO has approximately 0.75 % duty cycle and 0.5 Hz frequency.
Note:
Production test firmware is downloaded through
uartboot_da1470x.bin
. After
the uartboot firmware is downloaded, the watchdog pin will be pulsed.
Test name
The name assigned for this test.
Pin
Select the GPIO that will be toggled.
GPIO power level
Sets the power level of the GPIOs.