( 5 / 12 )
4. Setting Up
This chapter describes how to set up the M37531T-ADS.
(1) Mount an emulator MCU on the M37531T-ADS. After checking the position of the No. 1 pin of
the emulator MCU, mount the emulator MCU.
Figure 4.1 Position of No. 1 pin of an M37531T-ADS's emulator MCU
(2) Connect the white cable and black cable of the emulation pod to RESET pin (TP3) and Vss pin
(TP2) of the M37531T-ADS respectively.
(3) Connect a power supply (not included) to Vcc pin of the M37531T-ADS. And connect the GND
output of the power supply to Vss pin.
(4) Do not connect the yellow cable of the emulation pod to Vcc pin (TP1).
Tables 4.1 lists the correspondence of the connector cables and signals, and Figure 4.2 shows the
connection.
Table 4.1 Connector cables of the M38000TL2-FPD and applicable signals
Cable color
White
Black
Yellow
Signal
RESET
Vss
Vcc (no connection)