background image

10.

 

Connect a USB cable between the micro USB Serial connector (CN5 UART) on the sub board and a USB port on 

the host PC. The board will enumerate in the Device Manager under Ports (COM & LPT) 

 Communications Port 

(COMn) as “RZA USB Serial Port”. The micro USB Serial connector (CN5 UART) on the sub board may be used to 

provide a serial console for the sample applications. 

If you have not previously installed another Renesas kit with this virtual serial port driver, or if the board enumerates 

as an “Unknown device,” then disconnect the board and install the “RZ/A2M Evaluation Board Kit inf File for USB to 

Serial Conversion IC” available from 

https://www.renesas.com/software/D6002724.html

  

a.

 

Note: Windows™ 10 / 8.1 / 8 / 7 users may see “User Account Control” dialog box. If applicable, enter 

the administrator password and click ‘Yes’. 

b.

 

The Windows™ driver signing dialog box may be displayed. Please accept the driver to continue. 

11.

 

Use any serial terminal (e.g. HyperTerminal, Tera Term or PuTTY), select the appropriate COM port and set the 

baud-rate to 115200 bps, Data bits to 8, Stop bits to 1, Parity to None and Flow as None. 

12.

 

Connect a USB cable between the mini USB Power connector (CN13 USB-F) on the sub board and a USB port on 

the host PC. 

13.

 

Apply power by moving SW1 away from the power jack; the blue power LED will illuminate. 

14.

 

Power down the system by moving SW1 towards the power jack. 

3.   Preparing the e

2

 studio development environment 

Renesas e

studio integrates various tools such as compiler, assembler, debugger and editor into a common graphical 

user interface. 

15.

 

Start e2 studio: 

Windows™ 7: Start Menu > All Programs > Renesas Electronics e2studio > e2 studio 
Windows™ 8.1 & 8: From Apps View  , Renesas Electronics e2studio > e2 studio 

Windows™ 10: Start Menu > All Apps > Renesas Electronics e2studio > e2 studio 

16.

 

In the ‘Select a workspace’ folder that appears, browse a suitable location and folder name to save your new 

workspace to. Click ‘OK’ to continue. 

17.

 

In the ‘Toolchain Registry’ dialog box select Renesas Toolchains and ensure that ‘GCC ARM Embedded 

6.3.1.20170620’ is selected. Click ‘Register’. A dialog box will appear "Selected Toolchains were successfully 

integrated with e2 studio". Click ‘OK’.  

18.

 

If the ‘Code Generator Registration’ dialog box is shown, click ‘OK’ and follow the on-screen instructions to restart 

e

2

 studio. This is required before the Code Generator can be used. 

19.

 

To learn more on how to use e

studio, open the program’s help files by using Help > Help Contents. 

 

4.   Next Step 

20.

 

In the e

studio Welcome screen, click the ‘Workbench’ arrow icon, on the far right.  

You are ready to download and program an application from the RZ/A2M Simple Applications Package 

(R01AN4494EJ). 

21.

 

Select one of the available application notes, and follow the instructions in the readme files, ensuring the correct 

switch and jumper settings are made before applying power. Recommendations: 

 ● If you have a display supporting 800x600 input, access the camera_display_sample (R01AN4477EJ). 

 ● If you want to quickly check the kit’s operation, access the blinky_osfree_sample (R01AN4321EJ). 

 

Содержание RZ/A2M

Страница 1: ...il the software support has been installed Internet access is required during the installation process 1 Software for this Renesas Evaluation Board Kit is available for download from 2 After download the installer will run and display the Welcome dialog box Follow the on screen instructions to install the IDE software selecting the RZ device family when prompted This process will take several minu...

Страница 2: ...era s ribbon cable The correct orientation is with the contacts on the ribbon cable facing the CPU and the blue insulated rectangle to the outside To hold the cable firmly push down on the top of the connector until it clips in place Pull tags to open Push centre to close 7 Connect the J Link LITE Segger debugger module to the debugger connector CN5 Coresight 20 on the CPU board using the ribbon c...

Страница 3: ...nment Renesas e2 studio integrates various tools such as compiler assembler debugger and editor into a common graphical user interface 15 Start e2 studio Windows 7 Start Menu All Programs Renesas Electronics e2studio e2 studio Windows 8 1 8 From Apps View Renesas Electronics e2studio e2 studio Windows 10 Start Menu All Apps Renesas Electronics e2studio e2 studio 16 In the Select a workspace folder...

Страница 4: ...EJ Sub Board User s Manual R20UT4398EJ 7 Support Online technical support and information is available at https www renesas com rza2mevb Technical Contact Details America techsupport america renesas com Europe https www renesas com eu en support contact html Global Japan https www renesas com support contact html 2018 2019 Renesas Electronics Europe Limited All rights reserved 2018 2019 Renesas El...

Отзывы: