3.1 Operating Mode
Among the operating modes specified by the CiA402 standard, the sample program supports the following
modes.
Table 3-1 List of Supported Operating Modes
Operating Mode
Support
Profile position mode
Available
Velocity mode (frequency converter)
Not available
Profile velocity mode
Not available
Profile torque mode
Not available
Homing mode
Available
Interpolated position mode
Not available
Cyclic synchronous position mode
Available
Cyclic synchronous velocity mode
Available
Cyclic synchronous torque mode
Not available
Cyclic synchronous torque mode with commutation angle
Not available
Manufacturer specific mode
Not available