4. Programming and Debug
22.
Select a sample code by left clicking on it (it is recommended to start with the tutorial
project), then click the arrow next to build button (hammer icon), and select
‘HardwareDebug’ from the drop down menu.
23.
e
2
studio will now build the project. Once this is complete, debugging can be started by
clicking the arrow next to debug button (bug icon), and selecting ‘Debug Configurations’.
24.
Click the symbol next to the entry ‘Renesas GDB Hardware Debugging’ to expand the list.
Select the configuration entry which matches the current project.
25.
Click the ‘Debugger’ tab, then the ‘Connection Settings’ secondary tab.
Review the settings listed in the screenshot below.
26.
Click the ‘Debug’ button to download the code to the target, and begin debugging.
27.
A firewall warning may be displayed for ‘e2-server-gdb.exe’. Select the check-box for ‘Private networks, such
as my home or work network’, and click ‘Allow access’.
28.
A User Account Control (UAC) dialog may be displayed. Enter the administrator password and click ‘Yes’.
29.
e
2
studio may ask you to change to the ‘Renesas Debug Perspective’, click ‘Yes’.
30.
Once the code has been downloaded, click the ‘Resume’ button to run the code up to the
first line of the main function,
Init_LCD();
Click ‘Resume’ again to run the target through the rest of the code.
31.
Click the ‘Suspend’ button. The program will stop and the source code will be opened at the
current program counter.
32.
To disconnect from the target board, click the ‘Disconnect’ button on the toolbar:
then select the C/C++ perspective (at the top right) to return to the editor view.
5. MAC Address
Before running any Ethernet demonstration sample code, refer to section 5.9 of the RSK+RX63N-256K User
Manual to configure the MAC address.
6. Next Step
After you have completed this quick start procedure, please review the tutorial and sample code that came
with the kit. The tutorial project will help you understand the device and development process using Renesas
Development Tools.
The Hardware manual supplied with this RSK+ is current at the time of publication. Please check for any
updates to the device manual from the Renesas internet site at
To learn more on how to use e
2
studio, open the program’s help files by using Help > Help Contents.
7. Renesas RX Compiler
The version of the compiler provided with this RSK+ is fully functional for 60 days and then code size limited
to 128kbytes of Code and Data. This restriction can be removed by purchasing a licenced copy of the tools.
8. User Manuals
The user manuals for this product can be found at the following locations:
Windows™7 and Vista:
Start Menu > All Programs > Renesas Electronics Tools > RSK+RX63N (256K) e2 studio > Manuals
Windows™8:
From the Apps View , all the manuals are located in “Renesas Electronics Tools”.
9. Support
Online technical support and information is available at:
Technical Contact Details
America:
Europe:
Japan:
© 2014 Renesas Electronics Europe Limited. All rights reserved.
© 2014 Renesas Electronics Corporation. All rights reserved.
© 2014 Renesas Solutions Corp. All rights reserved.
Website:
D013374_11_S01_V01