R01UH0822EJ0100 Rev.1.00
Page 857 of 1041
Jul 31, 2019
RX13T Group
26. 12-Bit A/D Converter (S12ADF)
x = Don’t care
Note 1. When self-diagnosis is used (ADCER.DIAGM = 1), A/D conversion of the discontinued channel is started after self-diagnosis.
Table 26.12
Group Priority Operation Setting and Operating Mode for Three Groups
(ADGSPCR.PGS = 1, ADGCTRGR.GRCE = 1)
ADGSPCR
Operation
GBRSCN
LGRRS
GBRP
0
x
0
Group priority operation for three groups (groups A, B, and C)
When a group A trigger is input, group B scan is completed (not restarted)
When a trigger for group A or B is input, group C scan is not completed (not restarted).
0
x
1
Group priority operation for three groups (groups A, B, and C)
When a group A trigger is input, group B scan is completed (not restarted)
Single scan for group C is started continuously without start trigger input. After group C scan is
discontinued, scan is restarted from the head of the channel selected with the ADANSC0
register after scan for groups A and B is completed.
1
0
0
Group priority operation for three groups (groups A, B, and C)
After group B scan is discontinued, scan is restarted from the head of the channel selected
with the ADANSB0 register after group A scan is completed.
After group C scan is discontinued, scan is restarted from the head of the channel selected
with the ADANSC0 register after scan for groups A and B is completed.
1
1
0
Group priority operation for three groups (groups A, B, and C)
After group B scan is discontinued, scan is restarted from the head of the channel selected
with the ADANSB0 register after group A scan is completed.
After group C scan is discontinued, scan is restarted from the channel on which scan was
discontinued*
, among the channels selected with the ADANSC0 register after scan for
groups A and B is completed.
1
0
1
Group priority operation for three groups (groups A, B, and C)
After group B scan is discontinued, scan is restarted from the head of the channel selected
with the ADANSB0 register after group A scan is completed.
Single scan for group C is started continuously without start trigger input. After group C scan is
discontinued, single scan is restarted from the head of the channel selected with the
ADANSC0 register after scan for groups A and B is completed.
1
1
1
Group priority operation for three groups (groups A, B, and C)
After scanning for group B is discontinued, once scanning for group A completes, scanning is
resumed starting from the channel on which scanning was discontinued*
, among those
channels selected with the ADANSB0 register.
Single scan for group C is started continuously without start trigger input. After group C scan is
discontinued, single scan is restarted from the channel on which scan was discontinued*
among the channels selected with the ADANSC0 register after scan for groups A and B is
completed.