RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
(5) Operation When Error Occurs in Normal Mode and Operation is Restarted in Complementary
PWM Mode
shows a case in which an error occurs in normal mode and operation is restarted in complementary PWM
mode after re-setting.
Figure 19.147
Error Occurrence in Normal Mode, Recovery in Complementary PWM Mode
(1) to (10) are the same as in
(11) Initialize the normal mode waveform generation block with the TIOR register.
(12) Disable operation of the normal mode waveform generation block with the TIOR register.
(13) Disable output in MTU3 and MTU4 with the TOERA register.
(14) Select the complementary PWM output level and enable or disable cyclic output with registers TOCR1A and
TOCR2A.
(15) Set complementary PWM mode.
(16) Enable output in MTU3 and MTU4 with the TOERA register.
(17) Set MTU output using the MPC and port mode registers (PMR) corresponding to the I/O ports.
(18) Restart operation by setting the TSTRA register.