![Renesas RX100 Series Скачать руководство пользователя страница 473](http://html.mh-extra.com/html/renesas/rx100-series/rx100-series_user-manual_1440500473.webp)
R01UH0822EJ0100 Rev.1.00
Page 473 of 1041
Jul 31, 2019
RX13T Group
19. Multi-Function Timer Pulse Unit 3 (MTU3c)
Note 1. Since PWM waveforms are generated in complementary PWM mode, MTU4.TGRA compare match not only with MTU4.TCNT
but also with MTU3.TCNT and TCNTSA is detected. Accordingly, when compare match with MTU3.TCNT and TCNTSA occurs,
TRGA4N is also generated.
When MTU3 and MTU 4 are made to operate in complementary PWM mode for generating an A/D converter start request, use
the A/D converter start request by compare match between MTU4.TCNT and MTU4.TADCORA/TADCORB.
Table 19.63
Interrupt Sources and A/D Converter Start Request Signals
Target Registers
Interrupt Source
A/D Converter Start Request Signal
MTU0.TGRA and MTU0.TCNT
Input capture/compare match
TRGA0N
MTU1.TGRA and MTU1.TCNT
TRGA1N
MTU2.TGRA and MTU2.TCNT
TRGA2N
MTU3.TGRA and MTU3.TCNT
TRGA3N
MTU4.TGRA and MTU4.TCNT
TRGA4N
MTU4.TCNT
MTU4.TCNT trough in complementary PWM mode
MTU0.TGRE and MTU0.TCNT
Compare match
TRG0N
MTU4.TADCORA and MTU4.TCNT
TRG4AN
MTU4.TADCORB and MTU4.TCNT
TRG4BN
MTU4.TADCORA and MTU4.TCNT,
MTU4.TADCORB and MTU4.TCNT
Compare match (interrupt skipping function 2)
TRG4ABN