R01UH0822EJ0100 Rev.1.00
Page 1005 of 1041
Jul 31, 2019
RX13T Group
32. Electrical Characteristics
32.4.4
Control Signal Timing
Note:
200 ns minimum in software standby mode.
Note 1. t
Pcyc
indicates the cycle of PCLKB.
Note 2. t
NMICK
indicates the cycle of the NMI digital filter sampling clock.
Note 3. t
IRQCK
indicates the cycle of the IRQi digital filter sampling clock (i = 0 to 5).
Figure 32.16
NMI Interrupt Input Timing
Figure 32.17
IRQ Interrupt Input Timing
Table 32.27
Control Signal Timing
Conditions: VCC = 2.7 V to 5.5 V, AVCC0 = VCC to 5.5 V, VSS = AVSS0 = 0 V, T
a
= –40 to +105°C
Item
Symbol
Min.
Typ.
Max.
Unit
Test Conditions
NMI pulse width
t
NMIW
200
—
—
ns
NMI digital filter disabled
(NMIFLTE.NFLTEN = 0)
2 × t
Pcyc
≤ 200 ns
2 × t
Pcyc
—
—
2 × t
Pcyc
> 200 ns
200
—
—
NMI digital filter enabled
(NMIFLTE.NFLTEN = 1)
3 × t
NMICK
≤ 200 ns
3.5 × t
NMICK
—
—
3 × t
NMICK
> 200 ns
IRQ pulse width
t
IRQW
200
—
—
ns
IRQ digital filter disabled
(IRQFLTE0.FLTENi = 0)
2 × t
Pcyc
≤ 200 ns
2 × t
Pcyc
—
—
2 × t
Pcyc
> 200 ns
200
—
—
IRQ digital filter enabled
(IRQFLTE0.FLTENi = 1)
3 × t
IRQCK
≤ 200 ns
3.5 × t
IRQCK
—
—
3 × t
IRQCK
> 200 ns
NMI
t
NMIW
t
NMIW
IRQi
t
IRQW
t
IRQW