23. Multi-Function Timer Pulse Unit 2 (MTU2a)
23.2.19
Timer Output Level Buffer Registers (TOLBR)
The TOLBR registers function as buffer registers for the TOCR2 register and specify the PWM output level in
complementary PWM mode and reset-synchronized PWM mode.
shows an example of the PWM output level setting procedure in buffer operation.
Figure 23.3
Example of PWM Output Level Setting Procedure in Buffer Operation
Address(es): MTU.TOLBR 000D 0A36h
b7
b6
b5
b4
b3
b2
b1
b0
—
—
OLS3N OLS3P OLS2N OLS2P OLS1N OLS1P
Value after reset:
0
0
0
0
0
0
0
0
Bit
Symbol
Bit Name
Description
R/W
b0
Output Level Select 1P
Specify the buffer value to be transferred to the OLS1P bit in TOCR2.
R/W
b1
Output Level Select 1N
Specify the buffer value to be transferred to the OLS1N bit in TOCR2.
R/W
b2
Output Level Select 2P
Specify the buffer value to be transferred to the OLS2P bit in TOCR2.
R/W
b3
Output Level Select 2N
Specify the buffer value to be transferred to the OLS2N bit in TOCR2.
R/W
b4
Output Level Select 3P
Specify the buffer value to be transferred to the OLS3P bit in TOCR2.
R/W
b5
Output Level Select 3N
Specify the buffer value to be transferred to the OLS3N bit in TOCR2.
R/W
b7, b6
—
Reserved
These bits are read as 0. The write value should be 0.
R/W
[1] Set the TOCR1.TOCS bit to 1 to enable the TOCR2 register setting.
[2] Use the TOCR2.BF[1:0] bits to select the TOLBR buffer transfer timing.
Use bits OLS3N to OLS1N and OLS3P to OLS1P to specify the PWM
output levels.
[3] The TOLBR register initial setting must be the same value as specified
in bits OLS3N to OLS1N and OLS3P to OLS1P in the TOCR2 register.
Set the TOCS bit
Set the TOCR2 register
Set the TOLBR register
[1]
[2]
[3]