Renesas RTE7701422CFK144T000R Скачать руководство пользователя страница 2

RTE7701422CFK144T000R

 

User’s Manual 

R20UT3901EJ0100  Rev. 1.00 

 

Page 2 of 5 

Nov. 25, 2016 

 

5. Connection Procedure (See Figure 3) 

 

The procedure for connecting the RTE7701422CFK144T000R is shown below. 

 

(1) Mount the TC on the target system. 

 

(a)

 

Thinly apply a two-part curing-type epoxy-based adhesive (with curing 

taking at least thirty minutes) to the tips of the four protrusions from the bottom 

surface of the TC to be bonded to the target system (before using the adhesive, 

use alcohol or another suitable solvent to clean the surface of the target system). 

If you have difficulty aligning the positions of the leads of the TC with the pads 

on the target system, adopt the method described in (b) below. 

 

(b)

 

Use guide pins (NQ guide) to align positions attached to the TC by 

inserting the pins into the sockets for this purpose on the top of the TC. 

These are two or three non-through holes with a diameter of 1.0 mm. 

Refer to the drawings of your TC for more information on the socket positions. 

 

(c)

 

Solder the TC to the target system. If an MA is to be included, attach the 

MA before soldering the TC. The MA is used to prevent scattered flux or solder 

creating problems by becoming attached to the contact pins of the TC. 

 

 

Conditions for soldering 

 

Reflow: within 10 seconds at 260

°

 

Manual soldering: within 5 seconds at 350

°

C (per pin) 

Cautionary note: Do not wash the flux away by immersion or 

vapor treatment. 

 

(d)

 

Remove the guide pins or MA if they were used. 

 

(2) Attach the EC to the TC. 

Attach the EC above the TC after confirming there are neither cracks nor bends 

on the contact pins of the EC. 

 

(3) Secure the four corners of the EC with the YQ guide screws that came 
with the EC. 

 

 

Screws supplied with the EC 

 

Use the flathead screwdriver or torque driver supplied with the 

EC to secure, in order, the screws at the four corners. The 

tightening torque of a YQ guide should be no more than 0.054 

Nm. Securing the screws too tightly will lead to faulty 

connections. 

(4) Attach the pod to the RTE7701422CFK144T000R. 
(5) Attach the RTE7701422CFK144T000R to the EC. 

 

 Adjusting the height of the socket 

The height of the socket is adjustable by inserting an SA between  

the EC and the RTE7701422CFK144T000R. 

 

 

 

 

(1)

(2)

(3)

(5)

Use the flathead screwdriver

 in the figure indicates an example of the location of the pin that 

governs alignment. Be sure to align the pin one positions of the pad 

pattern on the board and the other parts.

(4)

YQ guides (four)

EC

TC

SA

  

 

      

  

   

      

 

              

      

          

  

 

Figure 3   Procedure for Connecting the 

RTE7701422CFK144T000R 

SA: Space adapter (sold separately, product of Renesas Electronics 

Corporation) 

Model Name: QB-144GJ-YS-01T 

EC: Emulator connector (sold separately, product of Renesas Electronics 

Corporation) 

Model name: QB-144GJ-YQ-01T 

*The QB-144GJ-YQ-01T package includes the YQ guides. 

TC: Target connector (sold separately, product of Renesas Electronics 

Corporation) 

Model name: QB-144GJ-NQ-01T 

MA: Mounting adapter (sold separately, product of Renesas Electronics 

Corporation) 

Model name: QB-144GJ -HQ-01T 

 

Pod (sold separately) 

RTE7701422CFK144T000R 

144-pin 0.5-mm-pitch 

(PLQP0144KA-A) pad patterns 

 

Отзывы: