RH850/U2A 144pin
8. Jumper Configuration Examples
R20UT5089ED0101 Rev.1.01
Page 34 of 56
July 08, 2022
8.2
Configuration Examples
8.2.1
General Settings
All of the following board configurations are based on these conditions:
•
Normal device operation mode (JP41[OPEN]: FLMD0 = L).
•
All voltages for all functions are activated.
•
Current measurements are not carried out, hence JP4, JP5, JP30 and JP31 are set.
•
Clock supply: assuming one of the resonators, coming with the board, are plugged into X1 socket.
•
For connection to external power supplies the 'banana-type' connectors CN8 (GND), CN9 (+5.0 V) and CN10 (+3.3
V) are assembled on the board.
•
If also the core supply voltage of 1.12 V will be supplied from an external power supply the connector CN11
(included in the package) must be assembled on the board.
8.2.2
Jumper Indicators
•
The
green
jumper JP41 for FLMD0 must always be open for a ‘normal’ (user mode and debug) operation of the
device.
•
The
red
jumpers are related to the power supply configuration.
Following jumper symbols are used:
−
: Jumper must not be set.
−
: Jumper must be set in the indicated position, in this case position [2-3]
−
: Jumper can be set to position [1-2] or position [2-3]
−
: Jumper with optional setting. The red setting [2-3] is the default setting. The blue setting [1-2] is the
optional setting.
Note
The pin 1 of a jumper can be identified by
•
a small circle near the jumper
•
a square soldering pad.
1 2 3
1 2 3
1 2 3