F1KM-S4, F1KH-D8 272pin PiggyBack board
Y-RH850-F1X-272PIN-PB-T2-V1
R20UT4009ED0100 Rev.1.0
8
2017-07-12
Figure 3
– Jumper setting overview
The
green
jumper
JP12 for FLMD
O0 always must be closed for a ‘normal’
(user mode and debug) operation of the device.
The
red jumpers
must be set for a “Voltage 1” (typ. +5.0V) operation of
the related device supply.
The
blue
jumper
must be set for a “Voltage 2” (typ. +3.3V) operation of
the related device supply.
Note:
The RH850/F1KH-D8 device requires a supply voltage of
3.3V
on its
REG1VCC
pin.
The RH850/F1KM-S4 device requires the
same supply
voltage to be set
to
REG0VCC
and
REG1VCC
.
See the section ‘Electrical Characteristics’ in the device User’s Manual for further
details.
For jumper settings related to the device operation mode, refer to the
chapter 6.2.