PC Tool operation procedure
PRELIMINARY
Notice This is not a final specification. Some
parametric limits are Subject to change.
3.9
DLMS over PRIME Test
3.9.1
Features
BN tool executes cycle reading test by connecting to ZIV DCU (PRIME v1.3.6).
3.9.2
Network Setting
(1) Power ON the G-CPX3 board of Base Node.
(2) Connect G-CPX3 board to host PC with USB cable.
(3) Connect host PC to DCU with LAN cable.
(4) Connect G-CPX3 board to Power Line.
(5) Push Reset Button on the G-CPX3 board.
(6) Execute
“prime14_cpx3_pc_bn_RevXXX.exe”.
(7)
Configure BN by “Settings” menu before connecting to COM Port. “DCU Connect”->”On” should be
set. DCU port number should be configured
by “DCU Connect”->“Port setting”
Figure 3.36 DCU Connect Menu Screen