background image

致尊敬的顾客

关于产品目录等资料中的旧公司名称

        NEC

电子公司与株式会社瑞萨科技于

2010

4

1

日进行业务整合(合并),整合后的

新公司暨“瑞萨电子公司”继承两家公司的所有业务。因此,本资料中虽还保留有旧公司
名称等标识,但是并不妨碍本资料的有效性,敬请谅解。

瑞萨电子公司网址:

http://www.renesas.com

2010

4

1

瑞萨电子公司

【业务咨询】

http://www.renesas.com/inquiry

【发行】瑞萨电子公司(

http://

www.renesas.com

Содержание R5F212ACSNFA

Страница 1: ...NEC 2010 4 1 http www renesas com 2010 4 1 http www renesas com inquiry http www renesas com...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China 16 R8C Series Flash MCU R8C 2A B Washer Platform Microcomputer Development Environment Sy...

Страница 4: ...03 0101 Rev 1 00 Page 2 Renesas System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Tel 86 21 6888 0556 Fax 86 21 6888 0559 Zi...

Страница 5: ...ions Beijing Co Ltd Shanghai Branch Date March 5 2008 Version 1 01 Copyright C Renesas System Solutions Beijing Co Ltd Shanghai Branch All rights reserved Trademarks a General All brand or product nam...

Страница 6: ...Improvement Policy Renesas System Solutions Beijing Co Ltd Shanghai Branch hereafter collectively referred to as Renesas pursues a policy of continuing improvement in design performance and safety of...

Страница 7: ...user assumes the entire risk of using the product Any liability of Renesas is limited exclusively to the replacement of defective materials or workmanship DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER...

Страница 8: ...hat may result from applications based on the examples described herein 2 No license is granted by implication or otherwise under any patents or other rights of any third party or Renesas 3 MEDICAL AP...

Страница 9: ...perate the platform board which also can help user to be familiar with Renesas R8C series MCU for washing machine application Section 1 About this platform Gives an general notification about using th...

Страница 10: ...2 Start Stop key introduction 19 2 1 3 Program key introduction 19 2 1 4 Function key introduction 19 2 1 5 Water Level key introduction 20 2 1 6 key introduction 20 2 1 7 OK Cancel key introduction 2...

Страница 11: ...Wash process 33 3 2 5 Rinse process 33 3 2 5 Spin process 34 3 2 6 Error detection and alarm 35 3 2 7 Washing stream 35 3 2 8 Softener inlet 36 3 2 9 Platform demo program 36 3 2 10 Power down recove...

Страница 12: ...alized is introduced in the following part of this manual To simulate the washer functions Jumpers and LEDs are used to represent some actual sensor inputs and outputs control And we also realized all...

Страница 13: ...LCD display 192 x 64 dots 2 Error detection and alarming 3 Auto power off function 4 Voice module interface 5 Weight texture detection 6 Water level detection 7 Automatism washing program 8 Unbalance...

Страница 14: ...all the triacs use Renesas products 3 AC power input port AC power controller K1 is not mounted on the board for security consideration because if K1 switched on system 5V is floating on 220V AC 4 AC...

Страница 15: ...etting menu for selected program the third level is dedicated water level special function and dedicated time parameter setting the fourth level is washer program running status displaying menu in whi...

Страница 16: ...eter such as water level soak time wash time and etc 3 Third level menu 4 Fourth level menu 4 Fourth level menu this level contains only 1 page which shows the platform running status user can browse...

Страница 17: ...interface reserved also can be use as other customized function 1 3 3 AC driving output port introduction Below picture shows the AC driving output ports and the function simulation LEDs which include...

Страница 18: ...as water level input on mean water reaches user setting value off means water does not reach user setting value 2 J2 Unbalance sensor input indication jumper in demo mode this jumper is used as unbala...

Страница 19: ...or the s w to determine which mode the platform is running after system power on jumper on means platform is running in debugging mode jumper off mean platform is running in demo mode 4 Key input incl...

Страница 20: ...g only and Start Stop key are valid Below table shows the valid and invalid key in relative program running mode Status Key Stand By Initial Run Stop Preset Demo Debug Run Power Program Function Water...

Страница 21: ...tatus like below Run Stop While in Stop all loading is off and the LCD displays the fourth level menu While Start Stop key pressed again the program is resumed 2 1 3 Program key introduction When Prog...

Страница 22: ...anging in water level 1 2 3 4 the soak time is 10 minutes in water level 5 6 7 the soak time is 20 minutes in water level 8 9 10 the soak time is 30 minutes Usually the rinse water level is one level...

Страница 23: ...OK key the highlighted program is selected and the second level menu will display 1 First page 2 Second page Note The special program can only be selected after the Tubedry function is enabled in Fun...

Страница 24: ...d there are 7 pages of menu that dedicatedly display the parameters according to the button that user selected in the second level menu The default menu page is Water Level by pressing or key user can...

Страница 25: ...displayed value is 1 time by pressing or key user can shift up and down the available rinse time values from 0 time to 4 times 2 2 3 5 Spin setting display This is the menu page for user to set the s...

Страница 26: ...the Start Stop key within 4 hours washing program will start the drain process and run the unfinished program For program left time calculation if save water function selected the time that the washer...

Страница 27: ...ameters by pressing Start Stop key the program will paused and allows user to set again the washing program in stop status The display content is as below by pressing key in 4th level cycle over Progr...

Страница 28: ...irst level menu 2 2 5 Save water menu introduction When save water function selected the washer program will not start the drain process in the end of selected rinse process The buzzer will buzz to re...

Страница 29: ...ach user setting value J2 Unbalance sensor input indication jumper in demo mode this jumper is used as unbalance detection jumper on mean unbalance happened jumper off mean unbalance not happened In d...

Страница 30: ...this Led on it indicates the CW triac is switched on 2 5 Automatic weight texture detection This function have not been enabled in release version of platform s w because this functions performance de...

Страница 31: ...status indication and alarming When Power key pressed the buzzer will buzz one time when save water function is executing the buzzer will buzz 20 times 0 5 second on 0 5 second off every 15 minutes a...

Страница 32: ...ame program again During automatic program running user can press Start Stop key to pause the program and set the program manually then by pressing Start Stop key the platform will run user set progra...

Страница 33: ...ing value 1 indicates the water reached the user setting value Below are the water supply function details While inlet process starting the Inlet triac switched on and supply water to user setting wat...

Страница 34: ...rocess is 2 minutes while this process exceeds 2 minutes washing program will stop time counting and if the process finished in less than two minutes the process running time still calculated as 2 min...

Страница 35: ...he full automatic program not enabled wash process starts the main stream washing motor cycle motor cycling time use wash set time subtracting 30 seconds and then runs 30 seconds balance washing motor...

Страница 36: ...the motor is turned off with drain valve on and the tube keep running by the inertial motion If the lid is open this process paused but it does not need to judge the balance status e While brake occu...

Страница 37: ...ng E0 Abnormal Drain Drain over 8 minutes E1 Abnormal lid open At the starting moment of wash rinse and spin process the lid is open E2 Abnormal spin Spin unbalance happen E3 Abnormal inlet Inlet over...

Страница 38: ...n stream and 20 seconds strong steam 3 2 8 Softener inlet In the last time rinse at the beginning of the inlet process there is a 10 seconds softener inlet process at the same time with water inlet Wh...

Страница 39: ...t the end of this manual Port Pin Comment P00 P03 LCD data line Port 0 P04 P05 LCD control line P10 P13 LCD data line P14 Softener LED output control P15 Reserved LED control P16 Load testing input Po...

Страница 40: ...ing off control P82 CW LED output control P83 Drain LED output control P84 Inlet LED output control P85 CCW LED output control I O port Port 8 P86 Reserved LED output control A D AN0 AN1 P06 P07 A D c...

Страница 41: ...03 0101 Rev 1 00 Page 39 Renesas System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Tel 86 21 6888 0556 Fax 86 21 6888 0559 Z...

Страница 42: ...ntent in certain RAM address of R8C 2A 2B to EEPROM for saving the variables that is on using at the time of voltage detection interrupt occurs and especially this function sets the power status flag...

Страница 43: ...with Renesas Hew and E8 debugger For detail introduction please refer to Renesas HEW and E8 debugger user manuals E8 97 x 65 x 21mm PC Windows98SE ME 2000 XP Install Tiny or SLP HEW Below picture sho...

Страница 44: ...d Pin 4 of K1 for connecting AC power to the output part then please connect the washing motor and or system valves Inlet or Drain with CN11 and CN12 Please keep in mind that while AC power is connect...

Страница 45: ...wer down recovery function For testing the unexpected power down recovery function of the platform the platform reset circuit need to be reworked It s recommend to use RC reset circuit instead of the...

Страница 46: ...as System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Appendix Below are the platform washing program time tables Tel 86 21 6...

Страница 47: ...03 0101 Rev 1 00 Page 45 Renesas System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Tel 86 21 6888 0556 Fax 86 21 6888 0559 Z...

Страница 48: ...03 0101 Rev 1 00 Page 46 Renesas System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Tel 86 21 6888 0556 Fax 86 21 6888 0559 Z...

Страница 49: ...03 0101 Rev 1 00 Page 47 Renesas System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Tel 86 21 6888 0556 Fax 86 21 6888 0559 Z...

Страница 50: ...03 0101 Rev 1 00 Page 48 Renesas System Solution Beijing Co Ltd Shanghai Branch Unit 207 AZIA Center No 1233 Lujiazui Ring Road Pudong District Shanghai China Tel 86 21 6888 0556 Fax 86 21 6888 0559 Z...

Страница 51: ...ally high quality and reliability such as safety systems or equipment or systems for transportation and traffic healthcare combustion control aerospace and aeronautics nuclear power or undersea commun...

Отзывы: