Rev. 1.00  Nov. 18, 2008  Page X of X 

REJ10J1937-0100 

 

WARNING

 

   

Observe the precautions listed below.  Failure to do so  

  will result in a FIRE HAZARD and will damage the user  
  system and the emulator product or will result in  
  PERSONAL INJURY.  The USER PROGRAM will be  
  LOST.   

  1.  Do not repair or remodel the emulator product by  
   

yourself for electric shock prevention and quality  

  

assurance. 

  2.  Always switch OFF the E200F emulator and user system 
   

before connecting or disconnecting any CABLES or  

  

PARTS. 

  3.  Always before connecting any CABLES, make sure that 
   

pin 1 on both sides are correctly aligned. 

 

 

 

Содержание R0E572546CBF10

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...H72543R User System Interface Converter Board R0E572546CBF10 Converter Board User s Manual User s Manual Rev 1 00 2008 11 Renesas Microcomputer Development Environment System SuperH Family SH72546RFCC...

Страница 4: ...Rev 1 00 Nov 18 2008 Page ii of iv REJ10J1937 0100...

Страница 5: ...h quality and reliability such as safety systems or equipment or systems for transportation and traffic healthcare combustion control aerospace and aeronautics nuclear power or undersea communication...

Страница 6: ...Rev 1 00 Nov 18 2008 Page iv of iv REJ10J1937 0100...

Страница 7: ...stem interface converter board is used to connect the evaluation chip unit to the user system This user system interface converter board must only be used for the above purpose Limited Applications Th...

Страница 8: ...ntegration test evaluation or some experiment else 2 In no event shall Renesas Solutions Corporation be liable for any consequence arising from the use of this emulator 3 Renesas Solutions Corporation...

Страница 9: ...ne who subsequently purchases the emulator product from you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXP...

Страница 10: ...ems caused by the user system All Rights Reserved 1 Circuitry and other examples described herein are meant merely to indicate the characteristics and performance of Renesas semiconductor products Ren...

Страница 11: ...duct This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER DANGER indic...

Страница 12: ...Page VI of X REJ10J1937 0100 means WARNING or CAUTION Example CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION Example DISASSEMBLY PROHIBITED means A FORCIBLE ACTION Example UNPLUG THE POWER CABLE...

Страница 13: ...shock This product is connected signal ground with frame ground If your developing product is transformless not having isolation transformer of AC power this may cause electric shock Also this may giv...

Страница 14: ...ry or damage to the equipment Warnings to Be Taken for This Product Do not disassemble or modify this product Personal injury due to electric shock may occur if this product is disassembled and modifi...

Страница 15: ...is always active while connecting the AC power cable Check if the power is supplied by the LED of AC adapter Cautions to Be Taken for This Product Use caution when handling this product Be careful not...

Страница 16: ...product or will result in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch...

Страница 17: ...nterface converter board that connects a user system for the SH72546RFCC SH72544R and SH72543R PRBG0272FA A package former package BP 272 to the SH72546RFCC SH72544R SH72543R SH72531 and SH72531FCC E2...

Страница 18: ...2 Assembling the User System Interface Cable 6 3 1 3 Connecting Common User System Interface Adaptor Cable Board Unit to EV Chip Unit 9 3 1 4 Installing to the IC Socket 11 3 2 Dimensions 12 3 2 1 Re...

Страница 19: ...rface converter board Please make sure you have all of these components when you unpack the product EV chip unit Expansion AUD trace unit Common user system interface adaptor cable board unit Common u...

Страница 20: ...user system interface adaptor cable R0E200F1CKL00 must be obtained separately 3 To mount the MCU directly on the user system use a LSPACK272Z20221RE02 top cover manufactured by Tokyo Eletech Corporat...

Страница 21: ...when using the emulator Table 2 Environmental Conditions Item Specifications Temperature Operating 10 to 35 C Storage 10 to 35 C Humidity Operating 35 to 80 RH no condensation Storage 35 to 80 RH no...

Страница 22: ...Section 2 Environmental Conditions Rev 1 00 Nov 18 2008 Page 4 of 18 REJ10J1937 0100...

Страница 23: ...Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are corr...

Страница 24: ...red dispersed flux in reflow for the IC socket Leave this protective tape in place until solder reflow has been completed 3 Since components that occupy large volumes close to the area for mounting of...

Страница 25: ...en connect the common user system interface adaptor cable cable unit to CONNECTOR2 Connect the common user system interface adaptor cable cable unit to CONNECTOR3 Connect the common user system interf...

Страница 26: ...a converter board or a adaptor board keep the board in place hold both sides of the connector at the head of the cable and apply vertical force to pull the cable away If the join is stiff so that the...

Страница 27: ...the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 Th...

Страница 28: ...3 User I F Connector 2 CN4 UCN1 UCN2 Ev chip unit Connector number Common user system interface adaptor cable board unit Ev chip unit connector side connector number Common user system interface adapt...

Страница 29: ...ocket for a PRBG0272FA A package on the user system Apply vertical force to fasten the parts together Take particular care to align the positions of pin 1 and the guide pin and to avoid the applicatio...

Страница 30: ...recommended dimensions for the mount pad footprint for the user system with an IC socket for a PRBG0272FA A package BSSOCKET272Z2021RE21N manufactured by Tokyo Eletech Corporation 1 0 x 19 19 0 1 0 0...

Страница 31: ...0 0 20 0 Unit mm 0 05 0 10 0 15 0 20 0 30 to 1 2 1 3 to 2 0 2 1 to 5 0 5 1 to 10 0 10 1 to 35 0 43 5 267 0 241 0 35 0 125 0 90 0 Emulation memory unit Ev chip unit Common user system interface adaptor...

Страница 32: ...stem interface converter board when it is connected to the user system are shown in figure 8 16 45 14 5 Unit mm 0 05 0 10 0 15 0 20 0 30 to 1 2 1 3 to 2 0 2 1 to 5 0 5 1 to 10 0 10 1 to 19 5 43 5 35 0...

Страница 33: ...to this user system interface converter board supports two kinds of clock sources as the MPU clock For details refer to the SH 2A SH 2 E200F Emulator User s Manual R0E0200F1EMU00E To use the emulator...

Страница 34: ...Section 3 Connection Procedures Rev 1 00 Nov 18 2008 Page 16 of 18 REJ10J1937 0100...

Страница 35: ...imensions of the recommended mount pad for the IC socket for this user system interface converter board are different from those of the MPU 4 This user system interface converter board is specifically...

Страница 36: ...Section 4 Notice Rev 1 00 Nov 18 2008 Page 18 of 18 REJ10J1937 0100...

Страница 37: ...anual Publication Date Rev 1 00 November 18 2008 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Customer Support Department Global Strategic Communication Div Renesas Solu...

Страница 38: ...7898 Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2377 3473 Renesas Technology Taiwan Co...

Страница 39: ......

Страница 40: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan SH72546RFCC SH72544R SH72543R User System Interface Converter Board REJ10J1937 0100 R0E572546CBF10 Converter Board User s Manual...

Отзывы: