background image

M301N2T-PRB User’s Manual 

2. Setup 

REJ10J0037-0100 Rev.1.00 Mar.16, 2005 

 

Page 22 of 48 

 
 

2.4 Connection the M30100T3-RPD-E 

The emulation pod for the M16C/1N Group MCUs consists of the two products, the M30100T3-RPD-E emulation pod main 
unit and the M301N2T-PRB pod probe. Figures 2.5 and 2.6 show how to connect the M301N2T-PRB and how to remove it, 
respectively. 

 

 

 

(1) Connect connectors J1 and J2 of the M301N2T-PRB 

to connectors J3 and J4 of the FLX64-PRB. 

 

 

(2) Fix the FLX64-PRB by the two screws. 
 

Figure 2.5 Connection the pod probe M301N2T-PRB 

 

 

 

(1) Unscrew the two screws of the M301N2T-PRB. 
 

 

(2) Remove the M301N2T-PRB from the FLX64-PRB. 

In this time, lift off the M301N2T-PRB vertically. 
Otherwise, the connector may cause a break. 

 

Figure 2.6 Removing the pod probe M301N2T-PRB 

 

IMPORTANT

 

Notes on Connecting the Pod Probe: 

 

 

Be sure to turn off the power before making connections. Otherwise, the internal circuits may be 

damaged. 

 

The small connectors of the M301N2T-PRB (J1 to J3) and FLX64-PRB (J3 and J4) are guaranteed for 

only 50 insertion/removal iterations 

 

When removing the M301N2T-PRB from the FLX64-PRB, lift off the M301N2T-PRB vertically. 

Otherwise, the connector may cause a break. 

 

F LX6 4 - PRB

M301N2T-PRB

F LX6 4 - PRB

M301N2T-PRB

Screw (x2)

Screw (x2)

Содержание Pod probe for M16C/1N Group M301N2T-PRB

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...M301N2T PRB User s Manual User s Manual Rev 1 00 2005 03 Pod probe for M16C 1N Group...

Страница 4: ...l inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or errors Please also pay attention to in...

Страница 5: ...All the components of this product are shown in 1 1 Package components page 12 If there is any question or doubt about this product contact your local distributor The related manuals for using this pr...

Страница 6: ...in your program development and evaluation stages In mass producing your program you have finished developing be sure to make a judgment on your own risk that it can be put to practical use by perfor...

Страница 7: ...tantly making efforts to improve the design and performance of this emulator Therefore the specification or design of this emulator or its user s manual may be changed without prior notice About the r...

Страница 8: ...an imminently dangerous situation that will cause death or heavy wound unless it is avoided However there are no instances of such danger for the product presented in this user s manual WARNING WARNIN...

Страница 9: ...at a reliable ground connection is maintained If you smell a strange odor hear an unusual sound or see smoke coming from this product then disconnect power immediately by unplugging the AC power cable...

Страница 10: ...ling This Product Use caution when handling the main unit Be careful not to apply a mechanical shock Do not touch the connector pins of the emulator main unit and the target MCU connector pins Static...

Страница 11: ...cuit Board 18 2 1 3 Using the Oscillator Circuit on the User System 18 2 2 Switch Settings 20 2 3 A D and D A Conversion Bypass Capacitors 21 2 4 Connection the M30100T3 RPD E 22 2 5 Connecting the Us...

Страница 12: ...ting Up the Emulator Debugger 37 Note on Stack Area 37 Note on MAP References and Settings 37 Note on Operation When Not Executing the User Program 37 Note on Making an MCU File 37 Notes on Address Ma...

Страница 13: ...lyzes contents of communication with the emulator debugger and controls the emulator hardware This program is installed in the flash memory in the emulator main unit This program is downloadable from...

Страница 14: ...use at a later time when sending your product for repair or other purposes Always use these packing box and cushion material when transporting this product If there is any question or doubt about the...

Страница 15: ...eparately available This emulation pod is for the M16C 10 Series MCUs 3 Emulator main unit PC4701 separately available This is a PC4701 series emulator main unit excluding PC4701L and PC4700L 4 Pitch...

Страница 16: ...initions of the system status LEDs Name Status Meaning ON Emulator system power supply is turned ON POWER OFF Emulator system power supply is turned OFF ON Emulator system is operating normally Flashi...

Страница 17: ...OWER OFF Power is not supplied to the target MCU ON Target MCU clock is supplied CLOCK OFF Target MCU clock is not supplied ON Target MCU is being reset or reset signal of the user system is held low...

Страница 18: ...ence setting Disassemble display C level debugging etc Real time trace function 32K cycle bus information recordable Bus external trigger time stamp 5 trace modes supported Break Before About After Fu...

Страница 19: ...temperature 10 to 60 C no dew Table 1 7 Operating environment of the host machine Item Description Host machine IBM PC AT compatibles OS Windows 98 Windows 2000 Windows Me Windows XP CPU Pentium III...

Страница 20: ...Supply The clock supply can be set in the Init dialog box when starting up the emulator debugger or inputting CLK command on the script window For pins XCIN XCOUT it is necessary to set the switches i...

Страница 21: ...circuit shown in Figure 2 2 where a resonator is connected between pins XIN and XOUT oscillation does not occur because a flexible cable buffer IC and other devices are used between the evaluation MC...

Страница 22: ...es and their factory settings Table 2 2 Switch settings of the FLX64 PRB Signal Switch Switch Setting of jumper switches PORT PORT XCIN XCIN JP1 P47 XCIN When using the P47 XCIN as a port Factory sett...

Страница 23: ...e 2 4 shows the position of the bypass capacitor Figure 2 4 Foot patterns of bypass capacitors for A D converter IMPORTANT Note on the A D Converter Function The characteristics of an A D converter di...

Страница 24: ...pod probe M301N2T PRB 1 Unscrew the two screws of the M301N2T PRB 2 Remove the M301N2T PRB from the FLX64 PRB In this time lift off the M301N2T PRB vertically Otherwise the connector may cause a break...

Страница 25: ...2005 Page 23 of 48 2 5 Connecting the User System Connect the emulation pod to the user system as shown in Figure 2 7 Figure 2 7 Connecting the user system M30102T PTC Pod probe M301N2T PRB 48 pin 0...

Страница 26: ...CK048SD are used for the HQPACK048SD do not use them for securing the YQPACK048SD 3 Connect the M30102T PTC along the YQ GUIDE s 4 Connect the M301N2T PRB Figure 2 8 Connecting the converter board M30...

Страница 27: ...a internal RAM area internal ROM area firmware file name The contents of the MCU file when using the M301N2F8FP 3KB RAM 64KB ROM are as follows An example of a file name M301N2T3 MCU 0 SFR area Start...

Страница 28: ...nd user system as simultaneously as possible 3 Do not leave either the emulator or user system powered on because of leakage current the internal circuits may be damaged 4 When turning on the power ag...

Страница 29: ...urned on check the following 1 After powering on the PC4701 before starting up the emulator debugger Make sure that the oscillator circuit board is properly installed in the PC4701 and it is oscillati...

Страница 30: ...ll start blinking 2 Start up the emulator debugger When the Init dialog box setup is complete the dialog which urges to download the firmware will appear Download the firmware following messages Requi...

Страница 31: ...in the emulation pod FLX64 PRB to the factory settings as shown in Figure 3 4 4 Within 2 seconds of activating power to the emulator press the system reset switch on the emulator front panel 5 Check t...

Страница 32: ...Whether the emulation pod and PC4701 are connected properly Whether the pod probe and emulation pod are connected properly Redownload the proper firmware Whether the switches in the M30100T3 RPD E an...

Страница 33: ...SYSTEM RES ET POWER CLOCK RESET RU N HALT POWER SA F E ERROR S TA T US O F SYSTEM RESET POWER CLOCK RESET RUN HALT PO WER SAF E ERROR S T A T U S OF SYSTEM RESET PO WER CLOCK RESET RU N HAL T POWER S...

Страница 34: ...is product 4 1 Target MCU Specifications Table 4 1 lists the specifications of target MCUs which can be debugged with this product Table 4 1 Specifications of target MCUs for the M301N2T PRB Item Desc...

Страница 35: ...ion interrupt vector table addresses Although data can be downloaded to the DBC single step or BRK instruction interrupt vector table addresses be aware that because the emulator system uses this area...

Страница 36: ...ulation pod If a maskable interrupt is requested when the user program is not being executed including when run time debugging is being performed the maskable interrupt request cannot be accepted beca...

Страница 37: ...of the Converter Board M30102T PTC Figure 4 2 shows the external dimensions and a sample foot pattern of the converter board M30102T PTC for a 48 pin 0 5 mm pitch LQFP Sample foot pattern Unit mm Figu...

Страница 38: ...he self check does not result normally excluding user system error the emulation pod or pod probe may be damaged Then contact your local distributor Be sure to disconnect the user system before execut...

Страница 39: ...e details see 3 1 2 Setting the Work Area page 25 Set the work area as MAP INT Note on Stack Area With this product a maximum 7 bytes of the interrupt stack is consumed Therefore ensure the 7 bytes ma...

Страница 40: ...cause communication errors Note on Watchdog Function The MCU s watchdog timer can be used only while programs are being executed To use it otherwise disable the watchdog timer Note on Protect Registe...

Страница 41: ...Interrupt Vector Area Do not perform the below debugging operations with the single step interrupt vector area addresses FFFECh FFFEFh 1 Step execution of instructions that access the single step int...

Страница 42: ...e power of PC4701 Not normal PC4701 Front panel LEDs 1 Check emulator system connections See 2 4 Connecting the M30100T3 RPD E page 22 2 Redownload the firmware See 3 3 Downloading Firmware page 28 3...

Страница 43: ...STATUS OF TARGET does not light up Connected Check that power Vcc and GND is properly supplied to the user system Disconnected 1 Check that both the main sub clocks are not set to External in the emu...

Страница 44: ...gger user s manual online manual 4 Check that the descriptions in the MCU file are correct See 3 1 1 Making an MCU File page 25 ERROR 16215 Cannot communicate with the debugging monitor Please execute...

Страница 45: ...oper firmware See 3 3 Downloading Firmware page 28 3 Choose the proper MCU file in the Init dialog box See the emulator debugger user s manual online manual 4 Check that the descriptions in the MCU fi...

Страница 46: ...to your local distributor SUPPORT product name SUPPORT TXT For prompt response please specify the following information 1 Operating environment Operating voltage V Operating frequency MHz Operating mo...

Страница 47: ...isuse of it Fires earthquakes and other unexpected disasters In the above cases contact your local distributor If your product is being leased consult the leasing company or the owner 6 3 Repair Provi...

Страница 48: ...should please send the faulty product along with the Repair Request Sheet to Renesas Solutions Corp Renesas Solutions When the faulty product is repaired it will be returned to the customer at the ear...

Страница 49: ...on Date Mar 16 2005 Rev 1 00 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Microcomputer Tool Development Department Renesas Solutions Corp 2005 Renesas Technology Corp a...

Страница 50: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M301N2T PRB REJ10J0037 0100 T User s Manual...