M3S-UFLA32R
UART Flash Memory Programming Utility
REJ10B0239-0140/Rev.1.40
Mar. 2007
Page 28 of 30
(2) In the "ID code setting" dialog, the ID code for verification is set.
Table 5.17.1 shows function list of operable and not operable functions according with the verify
result.
Choose [Specify ID code by hexadecimal] to set the ID code by hexadecimal.
Choose [Specify ID code by alphanumeric] to set the ID code by alphanumeric characters.
Click [OK] to enable the setting, and then close the "ID code setting" dialog.
Click [Cancel] to disable the setting, and then close the "ID code setting" dialog.
Note: In the 3218x Group and 3219x Group, 12-byte of the address H’84 to H’8F is enabled.
In the other MCU, 16-byte of the address H’84 to H’93 is enabled.
Figure 5.17.2 ID Code Setting Dialog
Table 5.17.1 Operable, Not Operable List
Function
ID code is corresponding or
every ID code in the MCU is FFh
ID code is not corresponding
Load YES
YES
Exit YES
YES
Lock Bit Information
YES
NO
Program YES
NO
Erase YES
NO
Block Erase
YES
NO
Lock Bit / Set
YES
NO
Lock Bit / Enable
YES
NO
Lock Bit / Disable
YES
NO
Blank Check
YES
NO
Verify Check
YES
NO
Batch processing / E.B.P.V.
YES
NO
Batch processing / E.P.
YES
NO
Batch processing / B.P.V.
YES
NO
Setting YES
YES
ID Code Setting
YES
YES
Version information
YES
YES
Note: YES: Operable, NO: Not operable