(3/6)
5. Connection Procedure
5.1 For Debugging with the Emulator
(1) Mount the NQPACK144SD-ND on the user system
(2) Connect the YQPACK144SD on the NQPACK144SD-ND.
(3) Secure the four corners of the YQPACK144SD with the
YQ-GUIDEs.
●
Do NOT use the screws included with the
YQPACK144SD.
●
Do NOT use the screwdriver included with the
NQPACK144SD-ND for fixing the YQ-GUIDEs. That
is used only for the HQPACK144SD.
(4) Set the clock select switch.
Refer to "6. Selecting a Clock" on page 5.
(5)
Mount the M32176T-PTC on the YQPACK144SD.
(6) Connect the emulation pod probe to the M32176T-PTC via
the SDI MCU control interface cable and the SDI trace
interface cable.
M32176T-PTC
(6) Interface cables
of the pod probe
(4) Clock select switch
Use a slotted screwdriver.
(1)
(2)
(3)
YQPACK144SD
NQPACK144SD-ND
YQ-GUIDE(×4)
(5)
144-pin 0.5mm pitch
(144P6Q-A) foot pattern
: No.1 pin
Be sure to match the position of No. 1 pin of
the foot pattern and each part.
Figure 5.1 Connection Procedure (1)