M306NKT3-RPD-E User’s Manual
2. Setup
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006
Page 28 of 104
2.7 Self-check
2.7.1 Self-check Procedure
To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 2.6.
(1) If the user system is connected, disconnect it.
(2) Set the switches in the emulation pod to the factory settings as shown in Figure 2.7.
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator front panel to switch
the emulator to maintenance mode.
(4) Check the SAFE LED starts blinking and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 30 seconds, the self-check has terminated normally.
Figure 2.6 LED display in the self-check procedure
Immediately after turning on the power
P OWE R
S AFE
ERROR
S T A T U S
O F
S YS T EM
RESET
P OWE R
C LOCK
RESE T
RUN
HAL T
P OWE R
SAF E
ERROR
S T A TU S OF
SYSTEM
RESET
POWE R
C L OCK
R E S E T
R U N
H A L T
P O WE R
SA F E
ER ROR
S T A T US O F
SYSTEM
RESET
P OWER
C L OC K
R E S E T
R UN
H AL T
P OWE R
S A F E
E R R OR
S T A TU S OF
SYSTEM
RESET
P OWE R
C L O C K
R E S E T
R U N
H A L T
P OWE R
S A F E
E R R OR
S T A TU S O F
SYSTEM
RESET
P O WE R
CL OCK
RE S E T
RU N
HA L T
(1 ) All the LEDs light
Completed normally
: Blinking
: On
: Off
Self - check
Target status error
System status error
(2 ) SAFE LED blinks
ERROR LED lights
SAFE and ERROR LED blink