M30290T-EPB User’s Manual
( 38 / 58 )
4.1 Turning On the Power
4.1.1 Checking Connections of the Emulator System
Before turning the power ON, check the connection of the interface cable to the host machine, PC7501, emulation probe,
and user system.
4.1.2 Turning ON/OFF the Power
z
Turn ON the power of the emulator and user system as simultaneously as possible.
Turn OFF the power of the emulator and user system as simultaneously as possible.
z
Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be
damaged.
z
When turning ON the power again after shutting OFF the power, wait for about 10 seconds.
4.1.3 Power Supply to the User System
z
Pin Vcc is connected in order to monitor user system voltage. For this reason, the emulator cannot supply power to
the user system. Therefore, provide the user system with a separate power supply.
z
The voltage of the user system should be as follows.
2.7
V
≤
Vcc
≤
5.5 V
z
Do not change the voltage of the user system after turning on the power.
Содержание M30290T-EPB
Страница 36: ...M30290T EPB User s Manual 36 58 MEMO...
Страница 56: ...M30290T EPB User s Manual 56 58 MEMO...
Страница 58: ......