M3028BT2-CPE User’s Manual
2. Setup
REJ10J1457-0300 Rev.3.00 July 22, 2009
Page 26 of 90
2.6.2 Checking Connections of the Emulator System
Before turning the power ON, check the connection of the interface cable to the host machine, emulator, and user system.
2.6.3 Power Supply to the User System
This emulator cannot supply the power to the user system. Therefore design your system so that the user system is powered
separately. This product consumes max. 500mA of electrical current from the user system. Please consider the capacity of the
power supply of the user system.
The voltage of the user system should be 2.7V
≤
VCC
≤
5.5V. Do not change the voltage of the user system after turning on
the power.
2.6.4 Turning ON/OFF the Power
Turn ON/OFF the power of the emulator and user system as simultaneously as possible.
Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be damaged.
When turning ON the power again after shutting OFF the power, wait for about 10 seconds.