background image

 

2-6-2, Ote-machi, Chiyoda-ku, Tokyo, 100-0004, Japan

H8SX/1653 Group E6000H TFP-120 

User System Interface Board 

HS1653ECN61H User’s Manual 

Содержание H8SX/1653

Страница 1: ...SX 1653 Group E6000H TFP 120 User System Interface Board HS1653ECN61H User s Manual Renesas Microcomputer Development Environment System HS1653ECN61HE Revision Date Dec 09 2005 Rev 2 00 REJ10B0200 020...

Страница 2: ......

Страница 3: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Страница 4: ......

Страница 5: ...er system interface board must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy o...

Страница 6: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Страница 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Страница 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Страница 9: ...n PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000H emulator...

Страница 10: ...interface board that connects a user system for the H8SX 1653 TFP 120 package to the H8SX 1650 E6000H emulator HS1650EPH60H Emulation of the H8SX 1653 group is only possible when this user system inte...

Страница 11: ...Evaluation Chip Board 7 2 3 Connecting User System Interface Board to Evaluation Chip Board 8 2 4 Recommended Dimensions for User System Mount Pad Footprint 10 2 5 Dimensions for Evaluation Chip Board...

Страница 12: ...120 package Please make sure you have all of these components when unpacking Evaluation chip board Spacer User system interface board User system IC socket Screws M2 12 mm with flat washers for fasten...

Страница 13: ...tem interface board 1 2 IC socket 1 For the TFP 120 package to be mounted on the user system 3 Socket cover 1 For installing a TFP 120 packaged MCU 4 Screw M2 x 12 mm 4 For fastening cable head with f...

Страница 14: ...to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST CAUTION 1 Do not connect a 5 V signal to...

Страница 15: ...et for a TFP 120 package to the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 1 3 I...

Страница 16: ...tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in th...

Страница 17: ...ce board User system Pin 1 Screws M2 12 mm with flat washers for fastening cable head IC socket IC149 120 043 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 2 Connecting User System Interface...

Страница 18: ...rface board is connected to the user system be careful not to apply load Exchange the spacer 2 6MP 10 mm of the evaluation chip board with another spacer 2 6MP 25 mm provided for the user system inter...

Страница 19: ...d the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system inte...

Страница 20: ...ector No UCN1 UCN1 UCN2 UCN2 User system interface board Evaluation Chip Board Connector No Board Connector No Evaluation chip board Figure 4 Connecting User System Interface Board to Evaluation Chip...

Страница 21: ...stem with an IC socket for a TFP 120 package IC149 120 043 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s m...

Страница 22: ...for the evaluation chip board and the user system interface board are shown in figure 6 Unit mm Tolerance 0 5 mm 140 0 Evaluation chip board User system interface board 102 5 16 0 118 5 100 0 84 5 69...

Страница 23: ...ser system interface board to the user system are shown in figure 7 Unit mm Tolerance 1 0 mm 35 6 16 0 57 6 User system Evaluation chip board IC socket IC149 120 043 B51 manufactured by YAMAICHI ELECT...

Страница 24: ...lt in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST CAUTION When this emulator is used without connecting to th...

Страница 25: ...14 P1 SW1 ON USER OFF Figure 8 SW1 Jumper Socket Spacer 2 6MQ x 16 mm Figure 9 Attaching Spacers...

Страница 26: ...PM4 VBUS DrVcc DrVcc USD USD USD USD Power supply circuit EPM7128 1 k Figure 10 User System Interface Circuit 1 Note The power supply circuit shown above is turned on off by the setting of the SW1 jum...

Страница 27: ...3 P27 P23 P27 SN74CB3Q3306A SN74CB3Q3306A MCU User system Figure 11 User System Interface Circuit 2 MCU User system Sub MCU P14 P14 SN74CB3Q3306A TXD SN74CB3Q3306A Figure 12 User System Interface Circ...

Страница 28: ...17 MCU VHC244 UHC14 _RES Vcc User system EPM7128 EPM7128 _RES 47 k Figure 13 User System Interface Circuit 4...

Страница 29: ...of clock sources as the MCU clock For details refer to the H8SX 1650 E6000H Emulator User s Manual HS1650EPH60HE To use the emulator internal clock Select the clock in the emulator by the CLOCK comman...

Страница 30: ...aluation chip board Install the crystal oscillator into the crystal oscillator terminals on the evaluation chip board Evaluation chip board Crystal oscillator terminals Crystal oscillator Enlarged vie...

Страница 31: ...ose of the MCU 4 This user system interface board is specifically designed for the HS1650EPH60H emulator Do not use this board with any other emulator 5 When power is not supplied to the Vcc pin on th...

Страница 32: ...terface cable and user system 9 To connect the emulator to the user system ensure that the SW1 jumper pin is inserted to ON Failure to do so will damage the emulator product user system interface boar...

Страница 33: ...group when the user system interface board is connected to the emulator 1 The USB clock frequency is fixed to 48 MHz regardless of the EXTAL input 2 P14 cannot be used as a port if the serial output...

Страница 34: ...ce Board HS1653ECN61H Publication Date Rev 1 00 November 11 2004 Rev 2 00 December 9 2005 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Customer Support Department Global...

Страница 35: ...esas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Technology Taiwan Co Ltd 1...

Страница 36: ...2 6 2 Ote machi Chiyoda ku Tokyo 100 0004 Japan H8SX 1653 Group E6000H TFP 120 User System Interface Board HS1653ECN61H User s Manual...

Отзывы: