background image

 

Section 2   Connection Procedures 

2.1 

Connecting User System Interface Cable to Emulator Station 

WARNING

 

   

Observe the precautions listed below.  Failure to do so  

  will result in a FIRE HAZARD and will damage the user  
  system and the emulator product or will result in  
  PERSONAL INJURY.  The USER PROGRAM will be  
  LOST.   
  1.  Always switch OFF the user system and the emulator 
   

product before the USER SYSTEM INTERFACE CABLE  

   

is connected to or removed from any part.  Before  

   

connecting, make sure that pin 1 on both sides are  

   

correctly aligned.  

  2.  The user system interface cable dedicated to the  
   

emulator must be used.   

To connect the cable body to the emulator station, follow the instructions below. 

1.  Make sure the user system and emulator station are turned off. 

CAUTION 

   

When connecting or removing the user system interface  

  cable, apply force only in the direction suitable for  
  connection or removal, while making sure not to bend or  
  twist the cable or connectors.  Otherwise, the connectors  
  will be damaged. 

Содержание H8SX/1520 Series

Страница 1: ...H8SX 1520 Group FP 100M User System Interface Cable User s Manual Renesas Microcomputer Development Environment System HS1527ECH61H Rev 1 00 Revision Date Jan 12 2005 REJ10B0173 0100...

Страница 2: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Страница 3: ...H is a user system interface cable that connects an H8SX 1520 group E6000H emulator HS1527KEPH60H hereinafter referred to as the emulator to the IC socket for an FP 100M package for the H8SX 1520 grou...

Страница 4: ...IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for...

Страница 5: ...the user system Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP 100M package To emulator station Cable body User system IC socket Cable head Screws M2 6 x 1...

Страница 6: ...ity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP 100M package 4 Socket cover 1 For installing an FP 100M packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head with four...

Страница 7: ...M INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must b...

Страница 8: ...connector is correct firmly insert the cable body connector into the emulator station socket figure 2 E6000H HS1527KEPH60H emulator station RENESAS Cable body connector User system interface cable Fi...

Страница 9: ...sult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the...

Страница 10: ...rewdriver whose head matches the screw head 2 The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the s...

Страница 11: ...rnating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or...

Страница 12: ...8 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jigs User system Removing Figure 4 Fastening Cable Body...

Страница 13: ...th an IC socket for an FP 100M package IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount p...

Страница 14: ...ser System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 63 50 66 04 17 0 17 0 29 5 29 5 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User Syst...

Страница 15: ...fter connecting the user system interface cable head to the user system are shown in figure 7 16 0 21 5 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 100 054 B51 manufactured by YAMA...

Страница 16: ...head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Страница 17: ...13 MCU Pin 1 IC socket IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 6 mm with flat washers Socket cover Figure 8 Installing MCU to User System...

Страница 18: ...50 E6000H Emulator User s Manual HS1650EPH60HE To use the emulator internal clock Select the clock in the emulator by using the CLOCK command emulator command To use the external clock on the user sys...

Страница 19: ...lator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as...

Страница 20: ...ges of AVcc0 and AVcc1 refer to the H8SX 1520 Group Hardware Manual CAUTION Insert the jumper pin in the P4 short connector so that the higher voltage between AVcc0 and AVcc1 is selected Select either...

Страница 21: ...er System Interface Cable Publication Date Rev 1 00 January 12 2005 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas K...

Страница 22: ...Fax 44 1628 585 900 Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Tec...

Страница 23: ...H8SX 1520 Group FP 100M User System Interface Cable HS1527ECH61H User s Manual...

Отзывы: