background image

Section 4   Verifying Operation 

1.  When using the E6000 emulator (HS2148EPI61H) for the H8S/2148, H8S/2138, H8S/2128 

series, turn on the emulator according to the procedures described in the H8S Series E6000 
Emulator User's Manual (HS2000EPI61HE). 

2.  Verify the user system interface cable connections by accessing the external memory and ports 

to check the bus states of the pins with the MEMORY_FILL command (emulator command).  If 
an error is detected, recheck the soldered IC socket and the location of pin 1. 

3.  The emulator connected to this user system interface cable supports two kinds of clock sources 

as the MCU clock: an emulator internal clock and an external clock on the user system.  For 
details, refer to the H8S series E6000 Emulator User's Manual (HS2000EPI61HE). 

 

To use the emulator internal clock 
Select the clock in the emulator station as the system clock (

φ

), by using the CLOCK 

command (emulator command). 

 

To use the external clock on the user system 
Supply the external clock from the user system to the emulator.  Connect a crystal oscillator 
to the EXTAL and XTAL terminals for the system clock (

φ

).  Select the external clock as the 

system clock (

φ

), by using the CLOCK command (emulator command).  For details, refer to 

section 22, Clock Pulse Generator, in the H8S/2138 Series, H8S/2134 Series Hardware 
Manual. 

Figure 9 shows the oscillator circuit on the user system interface cable. 

R1  1 M

R2  270

HCU04

HCU04

To E6000 
emulator

XTAL

EXTAL

System clock

 

Figure 9   Oscillator Circuit 

 

14 

 

Содержание H8S/2138 Series

Страница 1: ...H8S 2138 Series TQFP 80C User System Interface Cable HS2138ECN61H for E6000 Emulator User s Manual HS2138ECN61HE C...

Страница 2: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Страница 3: ...microcomputer H8S 2138 series The HS2138ECN61H is a user system interface cable that connects an H8S 2148 H8S 2138 H8S 2128 series E6000 emulator HS2148EPI61H hereinafter referred to as the emulator...

Страница 4: ...et 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 5 2 2 4 Fastening Cable Head 6 2 2 5 Connecting Cable Body to Cable Head 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimens...

Страница 5: ...Use an IC149 080 058 B51 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the TFP 80C package IC socket on the user system Figure 1 shows the configuration of the HS2138ECN61H user system interf...

Страница 6: ...g cable head User system IC socket Cable head Screws M2 6 x 12 mm with flat washers Screws M2 6 x 8 mm with flat washers Socket cover To emulator station Cable body Figure 1 HS2138ECN61H User System I...

Страница 7: ...arks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the TFP 80C package 4 Socket cover 1 For installing an TFP 80C packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head wi...

Страница 8: ...age the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow the instructions below 1 Make sure...

Страница 9: ...e location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an TFP 80C package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Страница 10: ...a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fasten th...

Страница 11: ...Cable head User system IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 6 x 12 mm flat washer Pin 1 Figure 3 Connecting User System Interface Cable to User System 7...

Страница 12: ...2 2 5 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8...

Страница 13: ...th an IC socket for an TFP 80C package IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount p...

Страница 14: ...ensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Interface Cable...

Страница 15: ...after connecting the user system interface cable head to the user system are shown in figure 7 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 080 058 B51 manufactured by YAMAICHI ELE...

Страница 16: ...head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Страница 17: ...MCU Pin 1 IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 13...

Страница 18: ...l clock and an external clock on the user system For details refer to the H8S series E6000 Emulator User s Manual HS2000EPI61HE To use the emulator internal clock Select the clock in the emulator stat...

Страница 19: ...tal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the e...

Отзывы: