Connecting User System Interface Cable to Emulator Station 

WARNING

 

   

Always switch OFF the user system and the emulator  

  product before the USER SYSTEM INTERFACE CABLE  
  is connected to or removed from any part.  Before connecting,  
  make sure that pin 1 on both sides are correctly aligned.  Failure to  
  do so will damage the user system and the emulator product or will  
  result in PERSONAL INJURY.  The USER PROGRAM will be  
  LOST. 

To connect the cable body to the emulator station, follow the instructions below. 

1.  Make sure the user system and emulator station are turned off. 

2.  After making sure the direction of the cable body connector is correct, firmly insert the cable 

body connector into the emulator station socket (figure 2). 

60

00

 

Emulator station

E

Cable body

User system interface cable

Figure 2   Connecting User System Interface Cable to Emulator Station 

 

Содержание H8/330

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...H8 3337Y Series H8 3334 Series H8 338 Series H8 330 H8 350 QFP 80A User System Interface Cable HS3337ECH61H for E6000 Emulator User s Manual User s Manual...

Страница 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Страница 5: ...ries The HS3337ECH61H is a user system interface cable that connects an H8 300 series E6000 emulator HS3008EPI60H hereinafter referred to as the emulator to the IC socket for a QFP 80A package package...

Страница 6: ...et 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 5 2 2 4 Fastening Cable Head 6 2 2 5 Connecting Cable Body to Cable Head 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimens...

Страница 7: ...N Use an IC149 080 017 B5 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the FP 80A package IC socket on the user system Figure 1 shows the configuration of the HS3337ECH61H user system interf...

Страница 8: ...IC socket Cable head Screws M2 x 12 mm with flat washers Screws M2 x 8 mm with flat washers Socket cover for fastening cable head To emulator station Cable body Figure 1 HS3337ECH61H User System Inter...

Страница 9: ...marks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP 80A package 4 Socket cover 1 For installing an FP 80A packaged MCU 5 Screws M2 0 x 12 mm 4 For fastening cable head wit...

Страница 10: ...age the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable body to the emulator station follow the instructions below 1 Make sure...

Страница 11: ...the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 80A package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Страница 12: ...ghtening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contac...

Страница 13: ...en screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the...

Страница 14: ...2 2 5 Connecting Cable Body to Cable Head Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8...

Страница 15: ...h an IC socket for an FP 80A package IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad...

Страница 16: ...ensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Interface Cable...

Страница 17: ...s after connecting the user system interface cable head to the user system are shown in figure 7 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 080 017 B5 manufactured by YAMAICHI ELE...

Страница 18: ...ch the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduc...

Страница 19: ...MCU Pin 1 mark User system Screws M2 0 x 8 mm with flat washers Socket cover IC socket IC149 080 017 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 8 Installing MCU to User System 13...

Страница 20: ...00 Emulator User s Manual HS3008EPI60HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator command To use the external...

Страница 21: ...tal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the e...

Отзывы: