Connecting User System Interface Cable to User System 

WARNING

 

   

Always switch OFF the user system and the emulator  

  product before the USER SYSTEM INTERFACE CABLE  
  is connected to or removed from any part.  Before  
  connecting, make sure that pin 1 on both sides are correctly  
  aligned.  Failure to do so will damage the user system and  
  the emulator product or will result in PERSONAL INJURY.   
  The USER PROGRAM will be LOST. 

To connect the cable head to the user system, follow the instructions below. 

2.2.1 

Installing IC Socket 

After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of 
the IC socket for a TFP-80C package, and fasten it to the user system before soldering. 

2.2.2 

Soldering IC Socket 

After fastening, solder the IC socket for a TFP-80C package to the user system.  Be sure to 
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)   

2.2.3 

Inserting Cable Head 

CAUTION 

   

Check the location of pin 1 before inserting. 

Align pin 1 on the IC socket for a TFP-80C package on the user system with pin 1 on the user 
system interface cable head, and insert the user system interface cable head into the IC socket on 
the user system, as shown in figure 3.  

 

Содержание H8/3001 TFP-80C

Страница 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Страница 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Страница 3: ...H8 3001 TFP 80C User System Interface Cable HS3001ECN61H for E6000 Emulator User s Manual User s Manual...

Страница 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Страница 5: ...CN61H for the Renesas s original microprocessor H8 3001 The HS3001ECN61H is a user system interface cable that connects an H8 3052 series E6000 emulator HS3052EPI61H hereinafter referred to as the emu...

Страница 6: ...IC Socket 6 2 2 2 Soldering IC Socket 6 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 7 2 2 5 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions fo...

Страница 7: ...Use an IC149 080 058 B51 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the TFP 80C package IC socket on the user system Figure 1 shows the configuration of the HS3001ECN61H user system interf...

Страница 8: ...Figure 1 HS3001ECN61H User System Interface Cable 2...

Страница 9: ...Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the TFP 80C package 4 Socket cover 1 For installing an TFP 80C packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head with fo...

Страница 10: ...he emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interfa...

Страница 11: ...Figure 2 Connecting User System Interface Cable to Emulator Station 5...

Страница 12: ...the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for a TFP 80C package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket After...

Страница 13: ...by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fasten...

Страница 14: ...n 1 Cable head IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Screws M2 6 x 12 mm with flat washers User system Figure 3 Connecting User System Interface Cable to User System...

Страница 15: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 9...

Страница 16: ...th an IC socket for a TFP 80C package IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pa...

Страница 17: ...ser System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 45 7 48 6 4 0 4 2 2 63 5 63 5 17 4 17 4 29 0 29 0 Figure 6 Dimensions for User System Inte...

Страница 18: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 Figure 7 Resulting Dimensions after Connecti...

Страница 19: ...rew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with...

Страница 20: ...MCU Pin 1 IC socket IC149 080 058 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 14...

Страница 21: ...8 3052 Series E6000 Emulator User s Manual HS3052EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CLOCK command emulator command To...

Страница 22: ...th any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to...

Отзывы: